ADR bulk provision AP8

Bulk batteries: corrosion-resistant steel load compartment, not loaded above the walls; small plastics containers need a 0.8 m drop at -18 °C.

A Class 8 bulk provision for batteries. The load compartment design must allow for residual currents and impacts from the batteries, and it must be steel that resists the corrosive battery contents; less resistant steel is allowed with enough wall thickness or a resistant plastics lining. A note treats steel losing no more than 0.1 mm per year to the corrosive substances as resistant. The load may not rise above the top of the compartment walls. Small plastics containers are also allowed if, fully loaded, they survive a 0.8 m drop on a hard surface at -18 °C without breaking.

Limits
ValueApplies when
0.1 mm per yearmaximum progressive reduction for steel to count as resistant
0.8 mdrop height for small plastics containers, fully loaded
-18 °Ctemperature of the small plastics container drop test

Conditions

Refers to: 7.3.3.1.

Carried by 4 Table A entries

UN 2794 · UN 2795 · UN 2800 · UN 3028

Source: ADR 2025 (ECE/TRANS/352), Volume II, section 7.3.3.2, AP8, page 593.

Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.

ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.