ADR packing instruction LP902
Heading in ADR: “PACKING INSTRUCTION”
UN 3268 safety devices in rigid 50-series large packagings at packing group III level, or unpackaged between factory and assembly plant.
LP902 applies to UN 3268. Packaged articles may go in rigid large packagings at the packing group III performance level, types 50A, 50B, 50N, 50H, 50C, 50D, 50F and 50G, under 4.1.1 and 4.1.3, designed to stop the articles moving or operating in normal carriage. Articles may also travel without packaging, in purpose-built handling devices or cargo transport units, when moving to, from or between the place of manufacture and an assembly plant, including intermediate handling sites. Any pressure receptacle must satisfy the competent authority's requirements for its contents.
| Type | Code | Packing groups | Max capacity (L) | Max net mass (kg) |
|---|---|---|---|---|
| rigid large packaging | 50A, 50B, 50N, 50H, 50C, 50D, 50F, 50G | III | — | — |
Conditions
- (1) Packaged: the large packaging must prevent movement and inadvertent operation of the articles.
- (2) Unpackaged: allowed in dedicated handling devices or cargo transport units only on journeys to, from or between the manufacturing site and an assembly plant, including intermediate handling locations.
Note. packing_groups records the performance level the large packaging must meet.
Refers to: 4.1.1; 4.1.3.
Carried by 1 Table A entry
Source: ADR 2025 (ECE/TRANS/352), Volume II, section 4.1.4.3, LP902, page 160.
Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.
ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.