ADR packing instruction P110(b)
Heading in ADR: “P110(b) PACKING INSTRUCTION”
Explosives in conductive or metal/wood receptacles or bags, separated by dividing partitions, in wooden or plywood boxes (4C2, 4D, 4F).
Class 1 packing instruction: it sets out which inner, intermediate and outer packagings may be combined for the explosives assigned to it, and 4.1.1, 4.1.3 and the explosives rules of 4.1.5 apply on top. Inner receptacles of metal, wood, conductive rubber or conductive plastics, or bags of conductive rubber or plastics, are separated by metal, wood, plastics or fibreboard dividing partitions inside sift-proof natural wood, plywood or reconstituted wood boxes.
| Type | Code | Packing groups | Max capacity (L) | Max net mass (kg) |
|---|---|---|---|---|
| boxes (outer) — inner: inner: receptacles (metal, wood, conductive rubber, conductive plastics) or bags (conductive rubber, conductive plastics); intermediate: dividing partitions (metal, wood, plastics, fibreboard) | 4C2, 4D, 4F | — | — | — |
| special packing provisions referenced | PP42 |
|---|
Note. P110(a) is reserved: the UN Model Regulations version is not admitted for carriage under ADR.
Refers to: 4.1.1; 4.1.3; 4.1.5.
Carried by 7 Table A entries
UN 0074 · UN 0113 · UN 0114 · UN 0129 · UN 0130 · UN 0135 · UN 0224
Source: ADR 2025 (ECE/TRANS/352), Volume II, section 4.1.4.1, P110(b), page 58.
Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.
ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.