ADR packing instruction P401

Heading in ADR: “P401 PACKING INSTRUCTION”

Steel pressure receptacles tested at 6 bar with inert gas blanket, or combination packagings with threaded inners of max 1 l and 30 kg per outer.

Two options. (1) Steel pressure receptacles meeting 4.1.3.6, tested initially and every 10 years at 0.6 MPa (6 bar gauge) or more, with the liquid under an inert gas blanket of at least 20 kPa (0.2 bar) gauge. (2) Combination packagings: drums, boxes or jerricans of the listed types with glass, metal or plastics inners with threaded closures of up to 1 litre, each surrounded by inert cushioning and absorbent material able to take the whole contents, and no more than 30 kg net per outer. General rules 4.1.1 and 4.1.3 apply.

Limits
ValueApplies when
6 barminimum test pressure of steel pressure receptacles (0.6 MPa gauge)
0.2 barminimum inert gas blanket gauge pressure
1 lmaximum inner packaging capacity
30 kgmaximum net mass per outer packaging
Permitted packagings
TypeCodePacking groupsMax capacity (L)Max net mass (kg)
steel pressure receptacles — inner: subject to 4.1.3.6————
combination: drums — inner: glass, metal or plastics with threaded closures, max 1 l1A1, 1A2, 1B1, 1B2, 1N1, 1N2, 1H1, 1H2, 1D, 1G——30
combination: boxes — inner: glass, metal or plastics with threaded closures, max 1 l4A, 4B, 4N, 4C1, 4C2, 4D, 4F, 4G, 4H1, 4H2——30
combination: jerricans — inner: glass, metal or plastics with threaded closures, max 1 l3A1, 3A2, 3B1, 3B2, 3H1, 3H2——30
special packing provisions referencedRR7

Refers to: 4.1.1; 4.1.3; 4.1.3.6.

Carried by 5 Table A entries

UN 1183 · UN 1242 · UN 1295 · UN 2965 · UN 2988

Source: ADR 2025 (ECE/TRANS/352), Volume II, section 4.1.4.1, P401, page 108.

Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.

ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.