ADR special packing provision PP91
UN 1044 large fire extinguishers may go unpackaged if 4.1.3.8.1 (a)–(e) are met and valves and fittings are protected.
Under P003, large fire extinguishers (UN 1044) may also be carried without packaging. Conditions: 4.1.3.8.1 (a) to (e) must be satisfied; valve protection must use one of the methods in 4.1.6.8 (a) to (d); and any other equipment fitted must be guarded against accidental activation. "Large fire extinguishers" here are the ones covered by special provision 225, indents (c) to (e).
Note. Appears only in P003.
Refers to: 4.1.3.8.1; 4.1.6.8; special provision 225.
Carried by 1 Table A entry
Source: ADR 2025 (ECE/TRANS/352), Volume II, section 4.1.4.1, P003, PP91, page 54.
Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.
ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.