ADR special provision 291

Flammable liquefied gas must be inside refrigerating machine parts tested to 3 × working pressure; machines with under 12 kg of gas are outside ADR.

Flammable liquefied gases under this entry must be held within components of the refrigerating machine. Those components must be designed and tested to no less than three times the machine working pressure, and the machine must be built to hold the gas without the pressure parts bursting or cracking in normal carriage. Refrigerating machines and their components are exempt from ADR when they hold less than 12 kg of gas. Heat pumps may be treated as refrigerating machines for carriage.

Limits
ValueApplies when
3 times working pressureminimum design and test pressure of components
12 kggas content below which machines and components are exempt

Carried by 1 Table A entry

UN 3358

Source: ADR 2025 (ECE/TRANS/352), Volume I, section 3.3.1, special provision 291, page 619.

Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.

ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.