Radiation detectors holding this gas in non-refillable receptacles outside Chapter 6.2/P200 may travel if pressure, size, burst and packing limits are met.

Radiation detectors holding this gas in non-refillable pressure receptacles that do not meet Chapter 6.2 or P200 may still travel under this entry if conditions (a) to (g) are met. If conditions (a) to (f) are met and each detector receptacle holds no more than 50 ml, the detectors, including those inside radiation detection systems, are free of all other ADR requirements.

Limits
ValueApplies when
50 barmaximum working pressure per receptacle
12 litresmaximum receptacle capacity
3 times working pressureminimum burst pressure, relief device fitted
4 times working pressureminimum burst pressure, no relief device
1.2 metredrop test the complete package must survive
50 mlreceptacle capacity at or below which detectors meeting (a) to (f) are fully exempt

Conditions

documentsTransport document statement "Transport in accordance with special provision 378"

Note. The provision begins on page 633 and continues on page 634.

Refers to: Chapter 6.2; P200; 4.1.4.1.

Carried by 8 Table A entries

UN 1006 · UN 1013 · UN 1046 · UN 1056 · UN 1065 · UN 1066 · UN 1956 · UN 2036

Source: ADR 2025 (ECE/TRANS/352), Volume I, section 3.3.1, special provision 378, page 633.