ADR special provision 406

May be carried as limited quantities in pressure receptacles of up to 1 000 ml meeting P200, with test pressure × capacity ≤ 15.2 MPa·l, packed alone.

Substances under this entry may use the Chapter 3.4 limited quantity provisions when the pressure receptacles hold no more than 1 000 ml each. The receptacles must meet P200 of 4.1.4.1, their test pressure multiplied by capacity must not exceed 15.2 MPa·l (152 bar·l), and they may not be packed with other dangerous goods.

Limits
ValueApplies when
1000 mlmaximum pressure receptacle capacity
15.2 MPa·l (152 bar·l)maximum test pressure × capacity product

Refers to: Chapter 3.4; P200; 4.1.4.1.

Carried by 4 Table A entries

UN 1006 · UN 1013 · UN 1046 · UN 1066

Source: ADR 2025 (ECE/TRANS/352), Volume I, section 3.3.1, special provision 406, page 640.

Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.

ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.