Gas in sound metal capsules (sodors, sparklets) is outside ADR at ≤ 25 g per capsule, ≤ 0.75 g/cm³ and ≤ 0.5 % air.

The gas is exempt from ADR when every listed condition holds: no more than 0.5 % air in the gas phase; carried in metal capsules (sodors, sparklets) with no defects weakening them; the capsule closure is leakproof; no more than 25 g of gas per capsule; and no more than 0.75 g of gas per cm³ of capsule capacity.

Limits
ValueApplies when
0.5 % airmaximum air content in gaseous state
25 gmaximum gas per capsule
0.75 g per cm³maximum filling per unit of capsule capacity

Conditions

Carried by 2 Table A entries

UN 1013 · UN 1070

Source: ADR 2025 (ECE/TRANS/352), Volume I, section 3.3.1, special provision 584, page 645.