ADR tank code L10BH
ADR tank code for Classes 1 and 3–9: liquid tank, 10 bar, openings B, hermetically closed.
L10BH is decoded part by part from the 4.3.4.1.1 table for Classes 1 and 3–9. Part 1 "L" is a tank for liquid-state substances (liquids, or solids handed over molten); part 2 "10" is minimum calculation pressure of 10 bar (see 6.8.2.1.14). Part 3 "B" (openings): filling or discharge openings at the bottom, each with 3 closures. Part 4 "H" (safety valves/devices): the tank is hermetically closed (see 1.2.1). The code gives the least stringent tank accepted; others may be used under the hierarchy in 4.3.4.1.2.
| tank type: L | tank for liquid-state substances (liquids, or solids handed over molten) |
|---|---|
| calculation pressure: 10 | minimum calculation pressure of 10 bar (see 6.8.2.1.14) |
| openings: B | filling or discharge openings at the bottom, each with 3 closures |
| safety valves: H | hermetically closed (see 1.2.1) |
Note. Tank codes permitted in place of this one: see the rationalized approach and hierarchy in 4.3.4.1.2 (Volume II pages 217–222); not computed here.
Refers to: 4.3.4.1.1; 4.3.4.1.2; 6.8.2.1.14; 6.8.2.2.2; 6.8.2.2.6; 1.2.1.
Carried by 48 Table A entries
UN 1739 · UN 1754 · UN 1758 · UN 1759 · UN 1760 · UN 1777 · UN 1796 · UN 1826 · UN 1828 · UN 1829 · UN 1831 · UN 1836 · UN 1903 · UN 2030 · UN 2031 · UN 2032 · UN 2054 · UN 2240 · UN 2401 · UN 2430 and 28 more UN numbers
Source: ADR 2025 (ECE/TRANS/352), Volume II, section 4.3.4.1.1, tank code L10BH, page 219.
Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.
ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.