ADR portable tank provision TP2

Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula).

Filling of the portable tank is capped at the degree of filling given in 4.2.1.9.3, expressed as 95 divided by (1 + a factor × (tr − tf)).

Conditions

Note. The factor in front of (tr − tf) is not legible in the extracted text; its definition is in 4.2.1.9.

Refers to: 4.2.1.9.3.

Carried by 616 Table A entries

UN 1052 · UN 1089 · UN 1092 · UN 1093 · UN 1098 · UN 1099 · UN 1100 · UN 1108 · UN 1131 · UN 1135 · UN 1143 · UN 1144 · UN 1150 · UN 1155 · UN 1162 · UN 1163 · UN 1164 · UN 1167 · UN 1181 · UN 1182 and 454 more UN numbers

Source: ADR 2025 (ECE/TRANS/352), Volume II, section 4.2.5.3, TP2, page 200.

Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.

ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.