ADR tank special provision TE26

Flammable refrigerated liquefied gas tanks: every filling and discharge connection needs an instant-closing automatic stop-valve close to the tank.

On tanks for flammable refrigerated liquefied gases, each filling and discharge connection, vapour-phase connections included, must have an automatic stop-valve that closes instantly (see 6.8.3.2.3), placed as near the tank as it can be.

equipmentinstant closing automatic stop-valve on every filling and discharge connection

Refers to: 6.8.3.2.3.

Carried by 6 Table A entries

UN 1038 · UN 1961 · UN 1966 · UN 1972 · UN 3138 · UN 3312

Source: ADR 2025 (ECE/TRANS/352), Volume II, section 6.8.4 (b), TE26, page 537.

Paraphrase in FreightUtils' own words, not the official text. Machine-reviewed: two independent readings of the UNECE text, compared with this record, agreed with it; no person has reviewed it yet.

Amended in ADR 2027 (ECE/TRANS/WP.15/274/Add.1, PDF p. 13) — this meaning is the ADR 2025 text. The consolidated ADR 2027 text is not yet published, so no ADR 2027 meaning is given here.