ADR tank special provision TT10

Periodic inspections every three years at most for fixed and demountable tanks, every two and a half years for tank-containers.

The periodic inspection under 6.8.2.4.2 is due no later than every three years in the left-hand column and every two and a half years in the right-hand column. Under 6.8.1.1, three years binds battery-vehicles, demountable tanks and tank-vehicles, and two and a half years binds MEGCs, tank swap bodies and tank-containers.

Limits
ValueApplies when
3 yearsleft column: battery-vehicles, demountable tanks, tank-vehicles
2½ yearstank-containers, tank swap bodies and MEGCs (right column), printed as "two and a half years"

Note. Under 6.8.1.1, text set in one column binds only the left-hand group (battery-vehicles, demountable tanks, tank-vehicles) or only the right-hand group (MEGCs, tank swap bodies, tank-containers).

Refers to: 6.8.2.4.2; 6.8.1.1.

Carried by 6 Table A entries

UN 1008 · UN 1017 · UN 1048 · UN 1050 · UN 1053 · UN 1079

Source: ADR 2025 (ECE/TRANS/352), Volume II, section 6.8.4 (d), TT10, page 538.

Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.

ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.