ADR special provision 201

Lighters and refills: country-of-filling rules, discharge protection, 85 % fill at 15 °C, sealed valves; max 10 g (lighters) or 65 g (refills) LPG.

Lighters and lighter refills must comply with the rules of the country where they were filled and be protected against accidental discharge. The liquid phase may fill no more than 85 % of the receptacle at 15 °C. Receptacles and closures must withstand twice the LPG pressure at 55 °C. Valves and ignition devices must be sealed, taped, fastened or designed so they cannot operate or leak in carriage. Waste lighters collected separately fall under special provision 654.

Limits
ValueApplies when
85 %maximum liquid fill of capacity at 15 °C
55 °Creference temperature for the twice-LPG-pressure strength requirement
10 gmaximum LPG per lighter
65 gmaximum LPG per lighter refill

Refers to: special provision 654.

Carried by 1 Table A entry

UN 1057

Source: ADR 2025 (ECE/TRANS/352), Volume I, section 3.3.1, special provision 201, page 613.