- Tunnels
- Tunnel code (D): in tanks, Prohibited in D, E; in other carriage, Prohibited in D, E. Categories A, B, C. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 2.1 (Gases: flammable gases) (ADR 5.2.2.2.2, label model No. 2.1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P002: General packing instruction for solids: combination, single, composite packagings and pressure receptacles, with net mass limits by packing group. Special packing provision PP84: UN 1057 needs rigid PG II outer packagings arranged to stop movement, accidental ignition and gas or liquid release. Special packing provision RR5: RID/ADR only: UN 1057 packages of 10 kg gross or less escape PP84 and need meet only some of the 4.1.1 general provisions. Mixed packing provision MP9: May share a combination outer packaging with other Class 2 goods, with other classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P002, 4.1.4.1, P002, PP84, 4.1.4.1, P002, RR5, 4.1.10.4, MP9; paraphrase, not yet reviewed)
- Carriage
- Loading provision CV9: Do not throw packages or subject them to impact; stow receptacles so they cannot tip over or fall. Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. (ADR 7.5.11, CV9, 8.5, S2; paraphrase, not yet reviewed)