ADR special provision 273
Self-heating-stabilized maneb need not go in Class 4.2 if a 1 m³ test sample held at 75 °C for 24 h neither self-ignites nor exceeds 200 °C inside.
Maneb and maneb preparations that have been stabilized against self-heating may be left out of Class 4.2 when testing shows the material is safe. The test uses a cube of 1 m³ of the substance kept at no less than 75 °C ± 2 °C for 24 hours. It passes if the cube does not ignite of its own accord and the centre temperature stays at or below 200 °C.
| Value | Applies when |
|---|---|
| 1 m³ | test sample volume (cube) |
| 75 °C | minimum test temperature, tolerance ± 2 °C |
| 24 hours | test duration |
| 200 °C | maximum temperature at the centre of the sample |
Carried by 1 Table A entry
Source: ADR 2025 (ECE/TRANS/352), Volume I, section 3.3.1, special provision 273, page 618.
Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.