- Tunnels
- Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 6.1 (Toxic substances), model 8 (Corrosive substances) (ADR 5.2.2.2.2, label model No. 6.1, 5.2.2.2.2, label model No. 8; paraphrase, not yet reviewed)
- Packing
- Packing instruction P600: Tear gas candles and toxic articles (UN 1700, 2016, 2017): PG II drums or boxes, articles separated, max 75 kg net. (ADR 4.1.4.1, P600; paraphrase, not yet reviewed)
- Carriage
- Loading provision CV13: After a leak or spill, clean (and if needed disinfect or decontaminate) the vehicle or container before reuse; check other goods for contamination. Loading provision CV28: Pointer: the provisions of 7.5.4 apply. Operation provision S9: Any quantity: avoid service stops near inhabited or busy places; longer stops there need authority consent. Operation provision S19: Chapter 8.4 vehicle supervision applies when the total mass in the vehicle exceeds 5 000 kg. (ADR 7.5.11, CV13, 7.5.11, CV28, 8.5, S9, 8.5, S19; paraphrase, not yet reviewed)