- Tunnels
- Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 0: no 1.1.3.6 exemption applies (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.2 (Substances liable to spontaneous combustion) (ADR 5.2.2.2.2, label model No. 4.2; paraphrase, not yet reviewed)
- Packing
- Packing instruction P404: Pyrophoric solids: sealed metal (15 kg) or canned glass (1 kg) inners in 125 kg outers, metal or composite packagings to 150 kg gross, or pressure receptacles. Mixed packing provision MP13: Up to 3 kg per inner packaging and per package may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P404, 4.1.10.4, MP13; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V1: Packages must go on a closed or sheeted vehicle or in a closed or sheeted container; open vehicles and containers are not allowed. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 7.2.4, V1, 8.5, S20; paraphrase, not yet reviewed)