- Tunnels
- Tunnel code (D): in tanks, Prohibited in D, E; in other carriage, Prohibited in D, E. Categories A, B, C. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.1 (Flammable solids, self-reactive and polymerizing substances, and solid desensitized explosives) (ADR 5.2.2.2.2, label model No. 4.1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P409: UN 2956, 3242, 3251: fibre drum (50 kg), fibreboard box with one plastics bag (50 kg), or 4G/1G with plastics inners of 5 kg (25 kg). Mixed packing provision MP2: No mixed packing: the goods must be alone in their package. (ADR 4.1.4.1, P409, 4.1.10.4, MP2; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T3: Portable tank, Class 1 and 3–9: test 2.65 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.2. Portable tank provision TP33: The assigned tank instruction covers granular/powdered solids and solids loaded hot but carried as a solid mass. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T3, 4.2.5.3, TP33, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Loading provision CV14: Shield goods from direct sun and heat in transit; store packages only in cool, well-ventilated places away from heat. Operation provision S24: Chapter 8.4 vehicle supervision applies when the total mass in the vehicle exceeds 100 kg. (ADR 7.5.11, CV14, 8.5, S24; paraphrase, not yet reviewed)