ADR tank special provision TC2

Shells and equipment of aluminium at least 99.5 % pure or a steel that will not decompose hydrogen peroxide; aluminium walls capped at 15 mm.

The shell and its equipment must be built from aluminium of 99.5 % purity or better, or from a suitable steel that does not cause hydrogen peroxide to break down. For shells of such aluminium, the wall need not be thicker than 15 mm, even if the 6.8.2.1.17 calculation gives more.

Limits
ValueApplies when
99.5 %minimum aluminium purity
15 mmwall thickness that need not be exceeded for aluminium shells

Refers to: 6.8.2.1.17.

Carried by 5 Table A entries

UN 2014 · UN 2015 · UN 2984 · UN 3149

Source: ADR 2025 (ECE/TRANS/352), Volume II, section 6.8.4 (a), TC2, page 533.

Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.

ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.