UN 3149

HYDROGEN PEROXIDE AND PEROXYACETIC ACID MIXTURE with acid(s), water and not more than 5 % peroxyacetic acid, STABILIZED

UN 3149 — ADR 2025 Table A: class 5.1, classification code OC1, packing group II, labels 5.1 +8, special provisions 196 553, limited quantity 1 L, excepted quantity E2, packing instructions P504 IBC02, transport category 2, tunnel restriction code (E), hazard identification number 58.

UNECE ADR 2025, ECE/TRANS/352 · checked 2026-10-28

Table A — ADR 2025 (ECE/TRANS/352), UN 3149
(1) UN No.3149
(2) Name and descriptionHYDROGEN PEROXIDE AND PEROXYACETIC ACID MIXTURE with acid(s), water and not more than 5 % peroxyacetic acid, STABILIZED
(3a) Class5.1
(3b) Classification codeOC1
(4) Packing groupII
(5) Labels5.1 +8
(6) Special provisions196 553
(7a) Limited quantities1 L
(7b) Excepted quantitiesE2
(8) Packaging: packing instructionsP504 IBC02
(9a) Packaging: special packing provisionsPP10 B5
(9b) Packaging: mixed packing provisionsMP15
(10) Portable tanks and bulk containers: instructionsT7
(11) Portable tanks and bulk containers: special provisionsTP2 TP6 TP24
(12) ADR tank: tank codeL4BV(+)
(13) ADR tank: special provisionsTU3 TC2 TE8 TE11 TT1
(14) Vehicle for tank carriageAT
(15) Transport category (Tunnel restriction code)2 (E)
(16) Special provisions for carriage: packages—
(17) Special provisions for carriage: bulk—
(18) Special provisions for carriage: loading, unloading and handlingCV24
(19) Special provisions for carriage: operation—
(20) Hazard identification No.58

ADR 2027 (accepted) — no change for UN 3149

ADR 2027 was accepted: depositary notification C.N.395.2026 (9 October 2026) records no objection to the amendments proposed by C.N.252.2026. It applies from 1 January 2027, and ADR 2025 may still be applied until 30 June 2027 (1.6.1.1). (C.N.395.2026)

ADR 2027: no Table A change for this entry (checked against ECE/TRANS/WP.15/274, Add.1 and Corr.1). Other parts of ADR 2027 may still affect its carriage.

ADR 2025 remains the edition FreightUtils serves and the one that applies until ADR 2027 takes effect on 1 January 2027; after that, ADR 2025 may still be applied until 30 June 2027 (1.6.1.1).

All ADR 2027 Table A changes →Check a list of UN numbers →

In plain words

Tunnels
Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
Small-load exemption
Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
Labels
Labels: model 5.1 (Oxidizing substances), model 8 (Corrosive substances) (ADR 5.2.2.2.2, label model No. 5.1, 5.2.2.2.2, label model No. 8; paraphrase, not yet reviewed)
Packing
Packing instruction P504: Combination packagings by inner material (glass 5 l/75 kg, plastics 30 l/75 kg, metal 40 l/125 or 225 kg), single drums 250 l, jerricans 60 l, composites. Packing instruction IBC02: Liquids under IBC02 may use metal (31A/31B/31N), rigid plastics (31H1/31H2) or composite 31HZ1 IBCs, with B and BB limits per UN number. Special packing provision PP10: Venting required: P001 for UN 1791 packing group II; P504 for UN 2014, 2984 and 3149. Special packing provision B5: UN 1791, 2014, 2984 and 3149 in IBCs need a venting device, with its inlet in the vapour space. Mixed packing provision MP15: Up to 3 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P504, 4.1.4.2, IBC02, 4.1.4.1, P001, PP10, 4.1.4.2, IBC02, B5, 4.1.10.4, MP15; paraphrase, not yet reviewed)
Tanks
Portable tank instruction T7: Portable tank, Class 1 and 3–9: test 4 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP2: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula). Portable tank provision TP6: Tank needs pressure-relief devices sized to its capacity and the substance so it cannot burst, even in a fire. Portable tank provision TP24: Tank may have an approved vapour-space device that vents slow-decomposition pressure but stops liquid leaking. Tank code L4BV(+): ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings B, valves/devices V, suffix (+). — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); B: filling or discharge openings at the bottom, each with 3 closures; V: has a 6.8.2.2.6 breather device but no flame-propagation protection, or is not explosion-pressure-shock resistant; (+): alternative use of the tank for other substances is allowed only where the certificate of type approval says so (3.2.1 column (12); 4.3.4.1.3) Tank provision TU3: Shell interior and every part touching the substance kept clean; no lubricant that could react dangerously with it on pumps or valves. Tank provision TC2: Shells and equipment of aluminium at least 99.5 % pure or a steel that will not decompose hydrogen peroxide; aluminium walls capped at 15 mm. Tank provision TE8: Connections to the external pipe-sockets must be of materials that do not cause hydrogen peroxide to decompose. Tank provision TE11: Shell and service equipment must keep out foreign matter, prevent leakage and stop dangerous decomposition pressure; a suitable safety valve suffices. Tank provision TT1: Pure aluminium tanks need initial and periodic hydraulic tests at only 250 kPa (2.5 bar) gauge. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T7, 4.2.5.3, TP2, 4.2.5.3, TP6, 4.2.5.3, TP24, 4.3.4.1.1, tank code L4BV(+), 4.3.5, TU3, 6.8.4 (a), TC2, 6.8.4 (b), TE8, 6.8.4 (b), TE11, 6.8.4 (d), TT1, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
Carriage
Loading provision CV24: Clean the vehicle or container of combustible debris before loading; no readily flammable stowage material. (ADR 7.5.11, CV24; paraphrase, not yet reviewed)

Assembled from FreightUtils' meanings of the Table A codes, not the official text. A statement marked “not yet reviewed” has not yet been checked against ADR by a person.

Class 5.1 — Oxidising Substances & Organic PeroxidesPacking Group II
UN 3149Class 5.1 — Oxidising Substances & Organic PeroxidesPG II
Packing Group
II
Medium danger
Classification Code
OC1
Tunnel Code
(E) meaning →
Code governing tunnel passage
Transport Category
2
For the 1,000-point rule (0 = highest restriction)
Hazard ID No.
58
Kemler code
Limited Quantity
1 L
Max per inner package for LQ relief
Excepted Quantity
E2
EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 2
×3 points per kg/L — up to 333 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
333 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
1 L
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E2
Max 30 ml/g per inner, 500 ml/g per outer package (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Special Provisions
SP 196, SP 553
May alter scope or limits — full text in ADR 2025 Chapter 3.3
Hazard Labels Required
Label 5.1Label 8

These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.

Special Provisions
SP 196SP 553

Refer to ADR 2025 Chapter 3.3 for full text of each provision.

Check if UN 3149 qualifies for 1.1.3.6 exemption
Calculate small load points and check exemption thresholds
Open calculator →

Other Oxidising Substances & Organic Peroxides near UN 3149 (Class 5.1)

UN 3099
OXIDIZING LIQUID, TOXIC, N.O.S.
UN 3100
OXIDIZING SOLID, SELF-HEATING, N…
UN 3121
OXIDIZING SOLID, WATER-REACTIVE,…
UN 3137
OXIDIZING SOLID, FLAMMABLE, N.O.S.
UN 3139
OXIDIZING LIQUID, N.O.S.
All Class 5.1 UN numbers →
Use this data programmatically
GET /api/adr?un=3149
View API Docs →
📅Data: UNECE ADR 2025 (ECE/TRANS/352), via EU Directive 2008/68/EC. Last verified October 2026

ADR reference data only. Classification is the consignor's legal responsibility. Consult a DGSA for compliance decisions.

Stay updated
ADR 2027 changes, new tools, and freight industry updates. No spam, unsubscribe anytime.
Related Tools
ADR 1.1.3.6 Exemption Calculator→LQ/EQ Checker→ADR Dangerous Goods Lookup→

Found an error? Let us know → contact@freightutils.com

← UN3148↑ Back to searchUN3150 →