- Tunnels
- Tunnel code (B/E): in tanks, Prohibited in B, C, D, E; in other carriage, Prohibited in E. Tanks: A only. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 5.1 (Oxidizing substances), model 8 (Corrosive substances) (ADR 5.2.2.2.2, label model No. 5.1, 5.2.2.2.2, label model No. 8; paraphrase, not yet reviewed)
- Packing
- Packing instruction P501: Hydrogen peroxide UN 2015: inners of 5 l (125 kg outer) or 2 l bagged (50 kg 4G/1G), single and composite packagings; vented, filled to 90 %. Mixed packing provision MP2: No mixed packing: the goods must be alone in their package. (ADR 4.1.4.1, P501, 4.1.10.4, MP2; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T9: Portable tank, Class 1 and 3–9: test 4 bar; shell 6 mm; relief Normal; bottom openings Not allowed. Portable tank provision TP2: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula). Portable tank provision TP6: Tank needs pressure-relief devices sized to its capacity and the substance so it cannot burst, even in a fire. Portable tank provision TP24: Tank may have an approved vapour-space device that vents slow-decomposition pressure but stops liquid leaking. Tank code L4BV(+): ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings B, valves/devices V, suffix (+). — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); B: filling or discharge openings at the bottom, each with 3 closures; V: has a 6.8.2.2.6 breather device but no flame-propagation protection, or is not explosion-pressure-shock resistant; (+): alternative use of the tank for other substances is allowed only where the certificate of type approval says so (3.2.1 column (12); 4.3.4.1.3) Tank provision TU3: Shell interior and every part touching the substance kept clean; no lubricant that could react dangerously with it on pumps or valves. Tank provision TU28: Tanks may be filled to no more than 95 % of capacity at a reference temperature of 15 °C. Tank provision TC2: Shells and equipment of aluminium at least 99.5 % pure or a steel that will not decompose hydrogen peroxide; aluminium walls capped at 15 mm. Tank provision TE7: Discharge needs two independent shut-offs in series: an approved quick-closing internal valve and an external valve, plus a blank flange. Tank provision TE8: Connections to the external pipe-sockets must be of materials that do not cause hydrogen peroxide to decompose. Tank provision TE9: A top-mounted shut-off device must stop pressure build-up from decomposition, liquid leakage and entry of foreign matter. Tank provision TT1: Pure aluminium tanks need initial and periodic hydraulic tests at only 250 kPa (2.5 bar) gauge. Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.2.5.2.6, portable tank instruction T9, 4.2.5.3, TP2, 4.2.5.3, TP6, 4.2.5.3, TP24, 4.3.4.1.1, tank code L4BV(+), 4.3.5, TU3, 4.3.5, TU28, 6.8.4 (a), TC2, 6.8.4 (b), TE7, 6.8.4 (b), TE8, 6.8.4 (b), TE9, 6.8.4 (d), TT1, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V5: These packages must not be carried in small containers. Loading provision CV24: Clean the vehicle or container of combustible debris before loading; no readily flammable stowage material. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 7.2.4, V5, 7.5.11, CV24, 8.5, S20; paraphrase, not yet reviewed)