- Tunnels
- Tunnel code (B/E): in tanks, Prohibited in B, C, D, E; in other carriage, Prohibited in E. Tanks: A only. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 5.1 (Oxidizing substances), model 8 (Corrosive substances) (ADR 5.2.2.2.2, label model No. 5.1, 5.2.2.2.2, label model No. 8; paraphrase, not yet reviewed)
- Packing
- Packing instruction P502: Oxidizing liquids: inners of 5 l in drums or boxes up to 125 kg (4H1 60 kg), single drums 250 l, jerricans 60 l, composite packagings. Special packing provision PP28: UN 1873: packaging parts in direct contact with perchloric acid must be glass or plastics. Mixed packing provision MP3: UN 1873 may be packed together with UN 1802. (ADR 4.1.4.1, P502, 4.1.4.1, P502, PP28, 4.1.10.4, MP3; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T10: Portable tank, Class 1 and 3–9: test 4 bar; shell 6 mm; relief See 6.7.2.8.3; bottom openings Not allowed. Portable tank provision TP1: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.2 (the 97-based formula). Tank code L4DN(+): ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings D, valves/devices N, suffix (+). — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); D: filled and discharged from the top; nothing opens below the liquid surface; N: has no 6.8.2.2.6 breather device and is not hermetically closed; (+): alternative use of the tank for other substances is allowed only where the certificate of type approval says so (3.2.1 column (12); 4.3.4.1.3) Tank provision TU3: Shell interior and every part touching the substance kept clean; no lubricant that could react dangerously with it on pumps or valves. Tank provision TU28: Tanks may be filled to no more than 95 % of capacity at a reference temperature of 15 °C. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T10, 4.2.5.3, TP1, 4.3.4.1.1, tank code L4DN(+), 4.3.5, TU3, 4.3.5, TU28, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Loading provision CV24: Clean the vehicle or container of combustible debris before loading; no readily flammable stowage material. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 7.5.11, CV24, 8.5, S20; paraphrase, not yet reviewed)