UN 3225

SELF-REACTIVE LIQUID TYPE D

UN 3225 — ADR 2025 Table A: class 4.1, classification code SR1, packing group —, labels 4.1, special provisions 194 274, limited quantity 125 ml, excepted quantity E0, packing instructions P520, transport category 2, tunnel restriction code (D), hazard identification number —.

UNECE ADR 2025, ECE/TRANS/352 · checked 2026-10-28

Table A — ADR 2025 (ECE/TRANS/352), UN 3225
(1) UN No.3225
(2) Name and descriptionSELF-REACTIVE LIQUID TYPE D
(3a) Class4.1
(3b) Classification codeSR1
(4) Packing group—
(5) Labels4.1
(6) Special provisions194 274
(7a) Limited quantities125 ml
(7b) Excepted quantitiesE0
(8) Packaging: packing instructionsP520
(9a) Packaging: special packing provisions—
(9b) Packaging: mixed packing provisionsMP2
(10) Portable tanks and bulk containers: instructions—
(11) Portable tanks and bulk containers: special provisions—
(12) ADR tank: tank code—
(13) ADR tank: special provisions—
(14) Vehicle for tank carriage—
(15) Transport category (Tunnel restriction code)2 (D)
(16) Special provisions for carriage: packagesV1
(17) Special provisions for carriage: bulk—
(18) Special provisions for carriage: loading, unloading and handlingCV15 CV22
(19) Special provisions for carriage: operationS19
(20) Hazard identification No.—

ADR 2027 (accepted) — no change for UN 3225

ADR 2027 was accepted: depositary notification C.N.395.2026 (9 October 2026) records no objection to the amendments proposed by C.N.252.2026. It applies from 1 January 2027, and ADR 2025 may still be applied until 30 June 2027 (1.6.1.1). (C.N.395.2026)

ADR 2027: no Table A change for this entry (checked against ECE/TRANS/WP.15/274, Add.1 and Corr.1). Other parts of ADR 2027 may still affect its carriage.

ADR 2025 remains the edition FreightUtils serves and the one that applies until ADR 2027 takes effect on 1 January 2027; after that, ADR 2025 may still be applied until 30 June 2027 (1.6.1.1).

All ADR 2027 Table A changes →Check a list of UN numbers →

In plain words

Tunnels
Tunnel code (D): in tanks, Prohibited in D, E; in other carriage, Prohibited in D, E. Categories A, B, C. (ADR 8.6.4; from the ADR table itself)
Small-load exemption
Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
Labels
Labels: model 4.1 (Flammable solids, self-reactive and polymerizing substances, and solid desensitized explosives) (ADR 5.2.2.2.2, label model No. 4.1; paraphrase, not yet reviewed)
Packing
Packing instruction P520: Organic peroxides (5.2) and self-reactive substances (4.1): packing methods OP1-OP8 set per-package quantity limits; metal only for OP7/OP8. Mixed packing provision MP2: No mixed packing: the goods must be alone in their package. (ADR 4.1.4.1, P520, 4.1.10.4, MP2; paraphrase, not yet reviewed)
Carriage
Carriage provision V1: Packages must go on a closed or sheeted vehicle or in a closed or sheeted container; open vehicles and containers are not allowed. Loading provision CV15: Pointer: the mixed-loading limits in 7.5.5.3 apply. Loading provision CV22: Load for free air circulation; above 5 000 kg per vehicle or large container, split into stacks ≤ 5 000 kg with ≥ 0.05 m gaps. Operation provision S19: Chapter 8.4 vehicle supervision applies when the total mass in the vehicle exceeds 5 000 kg. (ADR 7.2.4, V1, 7.5.11, CV15, 7.5.11, CV22, 8.5, S19; paraphrase, not yet reviewed)

Assembled from FreightUtils' meanings of the Table A codes, not the official text. A statement marked “not yet reviewed” has not yet been checked against ADR by a person.

Class 4.1 — Flammable Solids
UN 3225Class 4.1 — Flammable Solids
Packing Group
N/A
Not applicable
Classification Code
SR1
Tunnel Code
(D) meaning →
Code governing tunnel passage
Transport Category
2
For the 1,000-point rule (0 = highest restriction)
Hazard ID No.
—
Kemler code
Limited Quantity
125 ml
Max per inner package for LQ relief
Excepted Quantity
E0
EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 2
×3 points per kg/L — up to 333 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
333 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
125 ml
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E0
No excepted-quantity relief for this entry (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Special Provisions
SP 194, SP 274
May alter scope or limits — full text in ADR 2025 Chapter 3.3
Hazard Labels Required
Label 4.1

These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.

Special Provisions
SP 194SP 274

Refer to ADR 2025 Chapter 3.3 for full text of each provision.

Check if UN 3225 qualifies for 1.1.3.6 exemption
Calculate small load points and check exemption thresholds
Open calculator →

Other Flammable Solids near UN 3225 (Class 4.1)

UN 3222
SELF-REACTIVE SOLID TYPE B
UN 3223
SELF-REACTIVE LIQUID TYPE C
UN 3224
SELF-REACTIVE SOLID TYPE C
UN 3226
SELF-REACTIVE SOLID TYPE D
UN 3227
SELF-REACTIVE LIQUID TYPE E
All Class 4.1 UN numbers →
Use this data programmatically
GET /api/adr?un=3225
View API Docs →
📅Data: UNECE ADR 2025 (ECE/TRANS/352), via EU Directive 2008/68/EC. Last verified October 2026

ADR reference data only. Classification is the consignor's legal responsibility. Consult a DGSA for compliance decisions.

Stay updated
ADR 2027 changes, new tools, and freight industry updates. No spam, unsubscribe anytime.
Related Tools
ADR 1.1.3.6 Exemption Calculator→LQ/EQ Checker→ADR Dangerous Goods Lookup→

Found an error? Let us know → contact@freightutils.com

← UN3224↑ Back to searchUN3226 →