- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 6.1 (Toxic substances), model 8 (Corrosive substances) (ADR 5.2.2.2.2, label model No. 6.1, 5.2.2.2.2, label model No. 8; paraphrase, not yet reviewed)
- Packing
- Packing instruction P010: Glass or steel inner packagings in drums or boxes, steel single drums/jerricans, 6HA1 composites or steel pressure receptacles. Mixed packing provision MP15: Up to 3 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P010, 4.1.10.4, MP15; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T14: Portable tank, Class 1 and 3–9: test 6 bar; shell 6 mm; relief See 6.7.2.8.3; bottom openings Not allowed. Portable tank provision TP2: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula). Portable tank provision TP7: Air must be removed from the vapour space, by nitrogen or another method. Portable tank provision TP27: A 4 bar minimum test pressure tank may be used if 4 bar or less is shown acceptable under 6.7.2.1. Tank code L4BH: ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings B, hermetically closed. — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); B: filling or discharge openings at the bottom, each with 3 closures; H: hermetically closed (see 1.2.1) Tank provision TU15: Tank must not be used to carry foodstuffs, articles of consumption or animal feeds. Tank provision TE19: Top fittings recessed, valved or shielded against overturning; bottom fittings recessed 200 mm or rail-protected; rear fittings behind the 9.7.6 bumper. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T14, 4.2.5.3, TP2, 4.2.5.3, TP7, 4.2.5.3, TP27, 4.3.4.1.1, tank code L4BH, 4.3.5, TU15, 6.8.4 (b), TE19, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Loading provision CV13: After a leak or spill, clean (and if needed disinfect or decontaminate) the vehicle or container before reuse; check other goods for contamination. Loading provision CV28: Pointer: the provisions of 7.5.4 apply. Operation provision S9: Any quantity: avoid service stops near inhabited or busy places; longer stops there need authority consent. Operation provision S19: Chapter 8.4 vehicle supervision applies when the total mass in the vehicle exceeds 5 000 kg. (ADR 7.5.11, CV13, 7.5.11, CV28, 8.5, S9, 8.5, S19; paraphrase, not yet reviewed)