ADR portable tank provision TP29
A 1.5 bar minimum test pressure tank may be used if 1.5 bar or less is shown acceptable under 6.7.2.1.
A portable tank with a minimum test pressure of 1.5 bar is acceptable where it is shown, using the test pressure definition in 6.7.2.1, that 1.5 bar or less is enough.
| Value | Applies when |
|---|---|
| 1.5 bar | minimum test pressure of the tank that may be used |
Note. On page 201 the TP19–TP33 codes are printed in a column separate from their texts; texts were matched to codes in printed order (15 codes, 15 texts).
Refers to: 6.7.2.1.
Carried by 24 Table A entries
UN 1105 · UN 1120 · UN 1136 · UN 1224 · UN 1263 · UN 1268 · UN 1987 · UN 1989 · UN 1993 · UN 1999 · UN 2319 · UN 3066 · UN 3082 · UN 3216 · UN 3256 · UN 3257 · UN 3271 · UN 3272 · UN 3295 · UN 3336 and 1 more UN numbers
Source: ADR 2025 (ECE/TRANS/352), Volume II, section 4.2.5.3, TP29, page 201.
Paraphrase in FreightUtils' own words, not the official text. Not yet reviewed.
ADR 2027 amendments (accepted, applying from 1 January 2027) are not yet reflected on this page.