UN 1263Class 3 — Flammable LiquidsPG IVariant 1 of 6
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL (including paint thinning and reducing compound)
- Packing Group
- I
- High danger
- Classification Code
- F1
- Tunnel Code
- (D/E) meaning →
- Code governing tunnel passage
- Transport Category
- 1
- For the 1,000-point rule (0 = highest restriction)
- Hazard ID No.
- 33
- Kemler code
- Limited Quantity
- 500 ml
- Max per inner package for LQ relief
- Excepted Quantity
- E3
- EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 1
×50 points per kg/L — up to 20 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
20 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
500 ml
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E3
Max 30 ml/g per inner, 300 ml/g per outer package (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Special Provisions
SP 163, SP 367, SP 650
May alter scope or limits — full text in ADR 2025 Chapter 3.3
Hazard Labels Required
Label 3
These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.
Special Provisions
SP 163SP 367SP 650
Refer to ADR 2025 Chapter 3.3 for full text of each provision.
UN 1263Class 3 — Flammable LiquidsPG IIVariant 2 of 6
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL (including paint thinning and reducing compound) (vapour pressure at 50 °C more than 110 kPa)
- Packing Group
- II
- Medium danger
- Classification Code
- F1
- Tunnel Code
- (D/E) meaning →
- Code governing tunnel passage
- Transport Category
- 2
- For the 1,000-point rule (0 = highest restriction)
- Hazard ID No.
- 33
- Kemler code
- Limited Quantity
- 5 L
- Max per inner package for LQ relief
- Excepted Quantity
- E2
- EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 2
×3 points per kg/L — up to 333 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
333 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
5 L
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E2
Max 30 ml/g per inner, 500 ml/g per outer package (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Special Provisions
SP 163, SP 367, SP 640C, SP 650
May alter scope or limits — full text in ADR 2025 Chapter 3.3
Hazard Labels Required
Label 3
These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.
Special Provisions
SP 163SP 367SP 640CSP 650
Refer to ADR 2025 Chapter 3.3 for full text of each provision.
UN 1263Class 3 — Flammable LiquidsPG IIVariant 3 of 6
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL (including paint thinning and reducing compound) (vapour pressure at 50 °C not more than 110 kPa)
- Packing Group
- II
- Medium danger
- Classification Code
- F1
- Tunnel Code
- (D/E) meaning →
- Code governing tunnel passage
- Transport Category
- 2
- For the 1,000-point rule (0 = highest restriction)
- Hazard ID No.
- 33
- Kemler code
- Limited Quantity
- 5 L
- Max per inner package for LQ relief
- Excepted Quantity
- E2
- EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 2
×3 points per kg/L — up to 333 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
333 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
5 L
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E2
Max 30 ml/g per inner, 500 ml/g per outer package (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Special Provisions
SP 163, SP 367, SP 640D, SP 650
May alter scope or limits — full text in ADR 2025 Chapter 3.3
Hazard Labels Required
Label 3
These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.
Special Provisions
SP 163SP 367SP 640DSP 650
Refer to ADR 2025 Chapter 3.3 for full text of each provision.
UN 1263Class 3 — Flammable LiquidsPG IIIVariant 4 of 6
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL (including paint thinning and reducing compound)
- Packing Group
- III
- Low danger
- Classification Code
- F1
- Tunnel Code
- (D/E) meaning →
- Code governing tunnel passage
- Transport Category
- 3
- For the 1,000-point rule (0 = highest restriction)
- Hazard ID No.
- 30
- Kemler code
- Limited Quantity
- 5 L
- Max per inner package for LQ relief
- Excepted Quantity
- E1
- EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 3
×1 points per kg/L — up to 1,000 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
1,000 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
5 L
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E1
Max 30 ml/g per inner, 1,000 ml/g per outer package (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Special Provisions
SP 163, SP 367, SP 650
May alter scope or limits — full text in ADR 2025 Chapter 3.3
Hazard Labels Required
Label 3
These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.
Special Provisions
SP 163SP 367SP 650
Refer to ADR 2025 Chapter 3.3 for full text of each provision.
UN 1263Class 3 — Flammable LiquidsPG IIIVariant 5 of 6
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL (including paint thinning and reducing compound) (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa)
- Packing Group
- III
- Low danger
- Classification Code
- F1
- Tunnel Code
- (E) meaning →
- Code governing tunnel passage
- Transport Category
- 3
- For the 1,000-point rule (0 = highest restriction)
- Hazard ID No.
- —
- Kemler code
- Limited Quantity
- 5 L
- Max per inner package for LQ relief
- Excepted Quantity
- E1
- EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 3
×1 points per kg/L — up to 1,000 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
1,000 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
5 L
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E1
Max 30 ml/g per inner, 1,000 ml/g per outer package (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Special Provisions
SP 163, SP 367, SP 650
May alter scope or limits — full text in ADR 2025 Chapter 3.3
Hazard Labels Required
Label 3
These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.
Special Provisions
SP 163SP 367SP 650
Refer to ADR 2025 Chapter 3.3 for full text of each provision.
UN 1263Class 3 — Flammable LiquidsPG IIIVariant 6 of 6
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL (including paint thinning and reducing compound) (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa)
- Packing Group
- III
- Low danger
- Classification Code
- F1
- Tunnel Code
- (E) meaning →
- Code governing tunnel passage
- Transport Category
- 3
- For the 1,000-point rule (0 = highest restriction)
- Hazard ID No.
- —
- Kemler code
- Limited Quantity
- 5 L
- Max per inner package for LQ relief
- Excepted Quantity
- E1
- EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 3
×1 points per kg/L — up to 1,000 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
1,000 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
5 L
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E1
Max 30 ml/g per inner, 1,000 ml/g per outer package (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Special Provisions
SP 163, SP 367, SP 650
May alter scope or limits — full text in ADR 2025 Chapter 3.3
Hazard Labels Required
Label 3
These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.
Special Provisions
SP 163SP 367SP 650
Refer to ADR 2025 Chapter 3.3 for full text of each provision.