- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 3: at most 1000 per transport unit under 1.1.3.6, counted ×1 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P099: Only packagings approved for the goods by the competent authority; approval copy or a transport-document statement must accompany the load. Packing instruction IBC99: IBC99: only IBCs the competent authority has approved for the goods may be used, with proof of approval travelling with each consignment. Mixed packing provision MP2: No mixed packing: the goods must be alone in their package. (ADR 4.1.4.1, P099, 4.1.4.2, IBC99, 4.1.10.4, MP2; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T3: Portable tank, Class 1 and 3–9: test 2.65 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.2. Portable tank provision TP3: For solids above melting point and hot liquids, maximum filling (%) is set by 4.2.1.9.5: 95 × dr/df. Portable tank provision TP29: A 1.5 bar minimum test pressure tank may be used if 1.5 bar or less is shown acceptable under 6.7.2.1. Tank code LGAV: ADR tank code for Classes 1 and 3–9: liquid tank, G (general minimum), openings A, valves/devices V. — L: tank for liquid-state substances (liquids, or solids handed over molten); G: minimum calculation pressure under the general requirements of 6.8.2.1.14; A: filling or discharge openings at the bottom, each with 2 closures; V: has a 6.8.2.2.6 breather device but no flame-propagation protection, or is not explosion-pressure-shock resistant Tank provision TU35: Empty uncleaned tanks that held these substances are not subject to ADR once adequate measures have removed any hazard. Tank provision TE24: Bitumen tanks with a spray bar may replace the 6.8.2.2.2 closing device by a shut-off valve on the discharge pipe ahead of the spray bar. Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.2.5.2.6, portable tank instruction T3, 4.2.5.3, TP3, 4.2.5.3, TP29, 4.3.4.1.1, tank code LGAV, 4.3.5, TU35, 6.8.4 (b), TE24, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. (ADR 8.5, S2; paraphrase, not yet reviewed)