- Tunnels
- Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 3: at most 1000 per transport unit under 1.1.3.6, counted ×1 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 5.1 (Oxidizing substances) (ADR 5.2.2.2.2, label model No. 5.1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P504: Combination packagings by inner material (glass 5 l/75 kg, plastics 30 l/75 kg, metal 40 l/125 or 225 kg), single drums 250 l, jerricans 60 l, composites. Packing instruction IBC02: Liquids under IBC02 may use metal (31A/31B/31N), rigid plastics (31H1/31H2) or composite 31HZ1 IBCs, with B and BB limits per UN number. Packing instruction R001: R001 permits light gauge metal packagings 0A1 and 0A2 up to 40 l / 50 kg for packing groups II and III; packing group I is not allowed. Mixed packing provision MP15: Up to 3 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P504, 4.1.4.2, IBC02, 4.1.4.1, R001, 4.1.10.4, MP15; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T4: Portable tank, Class 1 and 3–9: test 2.65 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP1: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.2 (the 97-based formula). Portable tank provision TP29: A 1.5 bar minimum test pressure tank may be used if 1.5 bar or less is shown acceptable under 6.7.2.1. Tank code LGBV: ADR tank code for Classes 1 and 3–9: liquid tank, G (general minimum), openings B, valves/devices V. — L: tank for liquid-state substances (liquids, or solids handed over molten); G: minimum calculation pressure under the general requirements of 6.8.2.1.14; B: filling or discharge openings at the bottom, each with 3 closures; V: has a 6.8.2.2.6 breather device but no flame-propagation protection, or is not explosion-pressure-shock resistant Tank provision TU3: Shell interior and every part touching the substance kept clean; no lubricant that could react dangerously with it on pumps or valves. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T4, 4.2.5.3, TP1, 4.2.5.3, TP29, 4.3.4.1.1, tank code LGBV, 4.3.5, TU3, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Loading provision CV24: Clean the vehicle or container of combustible debris before loading; no readily flammable stowage material. (ADR 7.5.11, CV24; paraphrase, not yet reviewed)