- Tunnels
- Tunnel code (B/E): in tanks, Prohibited in B, C, D, E; in other carriage, Prohibited in E. Tanks: A only. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 0: no 1.1.3.6 exemption applies (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.2 (Substances liable to spontaneous combustion), model 6.1 (Toxic substances) (ADR 5.2.2.2.2, label model No. 4.2, 5.2.2.2.2, label model No. 6.1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P405: Phosphorus (UN 1381): wet in canned or glass inners in boxes, or metal drums/jerricans; dry fused in drums up to 400 kg. Mixed packing provision MP2: No mixed packing: the goods must be alone in their package. (ADR 4.1.4.1, P405, 4.1.10.4, MP2; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T9: Portable tank, Class 1 and 3–9: test 4 bar; shell 6 mm; relief Normal; bottom openings Not allowed. Portable tank provision TP3: For solids above melting point and hot liquids, maximum filling (%) is set by 4.2.1.9.5: 95 × dr/df. Portable tank provision TP31: May be carried in tanks only in the solid state. Tank code L10DH(+): ADR tank code for Classes 1 and 3–9: liquid tank, 10 bar, openings D, hermetically closed, suffix (+). — L: tank for liquid-state substances (liquids, or solids handed over molten); 10: minimum calculation pressure of 10 bar (see 6.8.2.1.14); D: filled and discharged from the top; nothing opens below the liquid surface; H: hermetically closed (see 1.2.1); (+): alternative use of the tank for other substances is allowed only where the certificate of type approval says so (3.2.1 column (12); 4.3.4.1.3) Tank provision TU14: Protective caps on the closures must be locked during carriage. Tank provision TU16: Uncleaned empty tanks must be handed over filled with a protective agent: nitrogen, water and nitrogen, or water at 96–98 %. Tank provision TU21: Substance must be protected by nitrogen, water and nitrogen, or a water layer of at least 12 cm, with filling limits of 96 % or 98 % at 60 °C. Tank provision TE3: Phosphorus tanks: external heating only, top-entry piping, lockable caps on openings and a level gauge for phosphorus and water. Tank provision TE21: Closures must be protected by lockable caps. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T9, 4.2.5.3, TP3, 4.2.5.3, TP31, 4.3.4.1.1, tank code L10DH(+), 4.3.5, TU14, 4.3.5, TU16, 4.3.5, TU21, 6.8.4 (b), TE3, 6.8.4 (b), TE21, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V1: Packages must go on a closed or sheeted vehicle or in a closed or sheeted container; open vehicles and containers are not allowed. Loading provision CV28: Pointer: the provisions of 7.5.4 apply. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 7.2.4, V1, 7.5.11, CV28, 8.5, S20; paraphrase, not yet reviewed)