- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 3: at most 1000 per transport unit under 1.1.3.6, counted ×1 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids), model 6.1 (Toxic substances) (ADR 5.2.2.2.2, label model No. 3, 5.2.2.2.2, label model No. 6.1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Packing instruction R001: R001 permits light gauge metal packagings 0A1 and 0A2 up to 40 l / 50 kg for packing groups II and III; packing group I is not allowed. Mixed packing provision MP19: Up to 5 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.4.1, R001, 4.1.10.4, MP19; paraphrase, not yet reviewed)
- Tanks
- Tank code L4BH: ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings B, hermetically closed. — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); B: filling or discharge openings at the bottom, each with 3 closures; H: hermetically closed (see 1.2.1) Tank provision TU15: Tank must not be used to carry foodstuffs, articles of consumption or animal feeds. Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.3.4.1.1, tank code L4BH, 4.3.5, TU15, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Loading provision CV13: After a leak or spill, clean (and if needed disinfect or decontaminate) the vehicle or container before reuse; check other goods for contamination. Loading provision CV28: Pointer: the provisions of 7.5.4 apply. Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. (ADR 7.5.11, CV13, 7.5.11, CV28, 8.5, S2; paraphrase, not yet reviewed)