- Tunnels
- Tunnel code (C/D): in tanks, Prohibited in C, D, E; in other carriage, Prohibited in D, E. Tanks: A, B. Packages: A, B, C. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 8 (Corrosive substances), model 6.1 (Toxic substances) (ADR 5.2.2.2.2, label model No. 8, 5.2.2.2.2, label model No. 6.1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P804: Bromine UN 1744: hermetically sealed; canned glass inners (25 kg gross), metal/PVDF inners of 5 l (75 kg gross), drum-in-drum, or pressure receptacles. Mixed packing provision MP2: No mixed packing: the goods must be alone in their package. (ADR 4.1.4.1, P804, 4.1.10.4, MP2; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T22: Portable tank, Class 1 and 3–9: test 10 bar; shell 10 mm; relief See 6.7.2.8.3; bottom openings Not allowed. Portable tank provision TP2: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula). Portable tank provision TP10: Lead lining at least 5 mm thick, tested yearly, or another approved lining; 3-month grace after lining inspection lapses. Tank code L21DH(+): ADR tank code for Classes 1 and 3–9: liquid tank, 21 bar, openings D, hermetically closed, suffix (+). — L: tank for liquid-state substances (liquids, or solids handed over molten); 21: minimum calculation pressure of 21 bar (see 6.8.2.1.14); D: filled and discharged from the top; nothing opens below the liquid surface; H: hermetically closed (see 1.2.1); (+): alternative use of the tank for other substances is allowed only where the certificate of type approval says so (3.2.1 column (12); 4.3.4.1.3) Tank provision TU14: Protective caps on the closures must be locked during carriage. Tank provision TU33: Fill to between 88 % and 92 % of capacity, or alternatively 2.86 kg per litre. Tank provision TU43: An empty uncleaned tank may travel up to three months past its lining inspection expiry, to reach that inspection before refilling. Tank provision TC5: Shells must have a lead lining at least 5 mm thick, or an equivalent lining. Tank provision TE21: Closures must be protected by lockable caps. Tank provision TT2: Shell lining condition must be inspected every year by an inspection body examining the inside of the shell. Tank provision TM3: Plate must also give the proper shipping name and, in kg, the highest load mass permitted for this substance. Tank provision TM5: Tanks must also show the month and year of the most recent internal shell inspection. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T22, 4.2.5.3, TP2, 4.2.5.3, TP10, 4.3.4.1.1, tank code L21DH(+), 4.3.5, TU14, 4.3.5, TU33, 4.3.5, TU43, 6.8.4 (a), TC5, 6.8.4 (b), TE21, 6.8.4 (d), TT2, 6.8.4 (e), TM3, 6.8.4 (e), TM5, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Loading provision CV13: After a leak or spill, clean (and if needed disinfect or decontaminate) the vehicle or container before reuse; check other goods for contamination. Loading provision CV28: Pointer: the provisions of 7.5.4 apply. Operation provision S14: Chapter 8.4 vehicle supervision applies for any amount of these substances. (ADR 7.5.11, CV13, 7.5.11, CV28, 8.5, S14; paraphrase, not yet reviewed)