- Tunnels
- Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Packing instruction IBC02: Liquids under IBC02 may use metal (31A/31B/31N), rigid plastics (31H1/31H2) or composite 31HZ1 IBCs, with B and BB limits per UN number. Packing instruction R001: R001 permits light gauge metal packagings 0A1 and 0A2 up to 40 l / 50 kg for packing groups II and III; packing group I is not allowed. Special packing provision B7: UN 1222 and 1865 may not be carried in IBCs larger than 450 litres, because of their explosion potential. Mixed packing provision MP19: Up to 5 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.4.2, IBC02, 4.1.4.1, R001, 4.1.4.2, IBC02, B7, 4.1.10.4, MP19; paraphrase, not yet reviewed)
- Carriage
- Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 8.5, S2, 8.5, S20; paraphrase, not yet reviewed)