- Tunnels
- Tunnel code (B): in tanks, Prohibited in B, C, D, E; in other carriage, Prohibited in B, C, D, E. Category A tunnels only. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 0: no 1.1.3.6 exemption applies (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 1 (Explosive substances or articles (Divisions 1.1, 1.2 and 1.3)) (ADR 5.2.2.2.2, label model No. 1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P144: Water-activated explosive articles in receptacles or partitions, inside metal, metal-lined wooden or plastics boxes or metal/plastics drums. Special packing provision PP77: UN 0248 and 0249 must be protected from water; unpackaged water-activated contrivances need two independent water barriers. Mixed packing provision MP1: Mixed packing only with goods of the same type in the same compatibility group. (ADR 4.1.4.1, P144, 4.1.4.1, P144, PP77, 4.1.10.4, MP1; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V2: Class 1 packages may only travel on EX/II or EX/III vehicles meeting Part 9; the quantity carried decides which type is needed (7.5.5.2). Loading provision CV1: Public-place loading/unloading: special permission needed inside built-up areas, advance notice to the authorities outside them. Loading provision CV2: Clean the loading surface thoroughly before loading; no fire or naked flame on, near, or while loading/unloading the vehicle. Loading provision CV3: Pointer: the Class 1 quantity limits per transport unit in 7.5.5.2 apply. Loading provision CV4: Compatibility group L substances and articles may only be carried as a full load. Operation provision S1: Class 1 operating rules: training, official escort, no smoking, loading places, 50 m spacing, supervision thresholds by division, locking. (ADR 7.2.4, V2, 7.5.11, CV1, 7.5.11, CV2, 7.5.11, CV3, 7.5.11, CV4, 8.5, S1; paraphrase, not yet reviewed)