- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Mixed packing provision MP7: Up to 5 litres per inner packaging may be mixed with same-class goods of other classification codes or with non-ADR goods. Mixed packing provision MP17: Up to 0.5 litre per inner and 1 litre per package may be mixed with other classes (not Class 7) that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.10.4, MP7, 4.1.10.4, MP17; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T11: Portable tank, Class 1 and 3–9: test 6 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP2: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula). Tank code L4BN: ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings B, valves/devices N. — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); B: filling or discharge openings at the bottom, each with 3 closures; N: has no 6.8.2.2.6 breather device and is not hermetically closed Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.2.5.2.6, portable tank instruction T11, 4.2.5.3, TP2, 4.3.4.1.1, tank code L4BN, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V8: Temperature control applies: follow 7.1.7; not applicable to inhibitor-stabilized 3.1.2.6 substances with SADT above 50 °C. Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. Operation provision S4: Temperature control: see 7.1.7; not applicable to inhibitor-stabilized 3.1.2.6 substances with SADT above 50 °C. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 7.2.4, V8, 8.5, S2, 8.5, S4, 8.5, S20; paraphrase, not yet reviewed)