- Tunnels
- Tunnel code (D): in tanks, Prohibited in D, E; in other carriage, Prohibited in D, E. Categories A, B, C. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.1 (Flammable solids, self-reactive and polymerizing substances, and solid desensitized explosives) (ADR 5.2.2.2.2, label model No. 4.1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P520: Organic peroxides (5.2) and self-reactive substances (4.1): packing methods OP1-OP8 set per-package quantity limits; metal only for OP7/OP8. Packing instruction IBC99: IBC99: only IBCs the competent authority has approved for the goods may be used, with proof of approval travelling with each consignment. Mixed packing provision MP2: No mixed packing: the goods must be alone in their package. (ADR 4.1.4.1, P520, 4.1.4.2, IBC99, 4.1.10.4, MP2; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T23: Portable tank rules for listed Class 4.1 self-reactive and Class 5.2 organic peroxide formulations: 4 bar test, extra 4.2.1.13 rules. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T23, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V1: Packages must go on a closed or sheeted vehicle or in a closed or sheeted container; open vehicles and containers are not allowed. Loading provision CV15: Pointer: the mixed-loading limits in 7.5.5.3 apply. Loading provision CV22: Load for free air circulation; above 5 000 kg per vehicle or large container, split into stacks ≤ 5 000 kg with ≥ 0.05 m gaps. (ADR 7.2.4, V1, 7.5.11, CV15, 7.5.11, CV22; paraphrase, not yet reviewed)