- Tunnels
- Tunnel code (B): in tanks, Prohibited in B, C, D, E; in other carriage, Prohibited in B, C, D, E. Category A tunnels only. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.1 (Flammable solids, self-reactive and polymerizing substances, and solid desensitized explosives), model 1 (Explosive substances or articles (Divisions 1.1, 1.2 and 1.3)) (ADR 5.2.2.2.2, label model No. 4.1, 5.2.2.2.2, label model No. 1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P520: Organic peroxides (5.2) and self-reactive substances (4.1): packing methods OP1-OP8 set per-package quantity limits; metal only for OP7/OP8. Special packing provision PP21: Certain type B or C self-reactive substances must use a packaging smaller than packing method OP5 or OP6 allows. Mixed packing provision MP2: No mixed packing: the goods must be alone in their package. (ADR 4.1.4.1, P520, 4.1.4.1, P520, PP21, 4.1.10.4, MP2; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V8: Temperature control applies: follow 7.1.7; not applicable to inhibitor-stabilized 3.1.2.6 substances with SADT above 50 °C. Loading provision CV15: Pointer: the mixed-loading limits in 7.5.5.3 apply. Loading provision CV20: Chapter 5.3, 7.1.7.4.7, 7.1.7.4.8 and V1 do not apply if packed to P520 OP1/OP2 and ≤ 10 kg per transport unit. Loading provision CV21: Temperature-controlled carriage: inspect unit, brief the carrier, carry enough refrigerant, keep packages accessible, hold control temperature throughout. Loading provision CV22: Load for free air circulation; above 5 000 kg per vehicle or large container, split into stacks ≤ 5 000 kg with ≥ 0.05 m gaps. Operation provision S4: Temperature control: see 7.1.7; not applicable to inhibitor-stabilized 3.1.2.6 substances with SADT above 50 °C. Operation provision S9: Any quantity: avoid service stops near inhabited or busy places; longer stops there need authority consent. Operation provision S16: Chapter 8.4 supervision above 500 kg in the vehicle; above 500 kg and under 1.10.3, supervise at all times per the security plan. (ADR 7.2.4, V8, 7.5.11, CV15, 7.5.11, CV20, 7.5.11, CV21, 7.5.11, CV22, 8.5, S4, 8.5, S9, 8.5, S16; paraphrase, not yet reviewed)