UN 3320Class 8 — Corrosive SubstancesPG IIVariant 1 of 2
SODIUM BOROHYDRIDE AND SODIUM HYDROXIDE SOLUTION, with not more than 12 % sodium borohydride and not more than 40 % sodium hydroxide by mass
- Packing Group
- II
- Medium danger
- Classification Code
- C5
- Tunnel Code
- (E) meaning →
- Code governing tunnel passage
- Transport Category
- 2
- For the 1,000-point rule (0 = highest restriction)
- Hazard ID No.
- 80
- Kemler code
- Limited Quantity
- 1 L
- Max per inner package for LQ relief
- Excepted Quantity
- E2
- EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 2
×3 points per kg/L — up to 333 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
333 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
1 L
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E2
Max 30 ml/g per inner, 500 ml/g per outer package (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Hazard Labels Required
Label 8
These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.
UN 3320Class 8 — Corrosive SubstancesPG IIIVariant 2 of 2
SODIUM BOROHYDRIDE AND SODIUM HYDROXIDE SOLUTION, with not more than 12 % sodium borohydride and not more than 40 % sodium hydroxide by mass
- Packing Group
- III
- Low danger
- Classification Code
- C5
- Tunnel Code
- (E) meaning →
- Code governing tunnel passage
- Transport Category
- 3
- For the 1,000-point rule (0 = highest restriction)
- Hazard ID No.
- 80
- Kemler code
- Limited Quantity
- 5 L
- Max per inner package for LQ relief
- Excepted Quantity
- E1
- EQ code for excepted quantity relief
Thresholds — why, not just the verdict
Transport Category
Category 3
×1 points per kg/L — up to 1,000 kg/L of this substance alone stays under the 1,000-point threshold
Per-substance max
1,000 kg/L
Per-substance maximum for 1.1.3.6 relief (1.1.3.6.3)
Limited Quantity
5 L
Max per inner packaging for LQ relief (Chapter 3.4)
Excepted Quantity
E1
Max 30 ml/g per inner, 1,000 ml/g per outer package (Chapter 3.5)
Tunnel Code
Governs which tunnel categories the load may pass
Hazard Labels Required
Label 8