- Tunnels
- Tunnel code (C5000D): in tanks, —; in other carriage, Net explosive mass over 5,000 kg per transport unit: prohibited in C, D, E. At or under 5,000 kg: prohibited in D, E. Class 1 quantity-qualified: A, B above 5,000 kg NEM; A, B, C at or under it. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 1 (Explosive substances or articles (Divisions 1.1, 1.2 and 1.3)) (ADR 5.2.2.2.2, label model No. 1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P114(b): Dry solid explosives: inner bags or receptacles, no intermediate packaging, outer wooden, plywood or fibreboard boxes or drums. Special packing provision PP50: Inner packagings are unnecessary when drums are the outer packaging (UN 0027 in P113; UN 0160, 0161, 0508 in P114(b)). Special packing provision PP52: UN 0160 and 0161 in metal drums: metal packagings must be built to prevent explosion from internal pressure rise. Mixed packing provision MP20: Class 1: mix only with substances of the same UN number, or under MP24; never with other classes or non-ADR goods. Mixed packing provision MP24: Explosives listed in the MP24 table may be mixed: 'A' pairs without a mass limit, 'B' pairs up to 50 kg of explosive substances in total. (ADR 4.1.4.1, P114(b), 4.1.4.1, P113, PP50, 4.1.4.1, P114(b), PP52, 4.1.10.4, MP20, 4.1.10.4, MP24; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V2: Class 1 packages may only travel on EX/II or EX/III vehicles meeting Part 9; the quantity carried decides which type is needed (7.5.5.2). Carriage provision V3: For free-flowing powders and for fireworks, the container floor must have a non-metallic surface or covering. Loading provision CV1: Public-place loading/unloading: special permission needed inside built-up areas, advance notice to the authorities outside them. Loading provision CV2: Clean the loading surface thoroughly before loading; no fire or naked flame on, near, or while loading/unloading the vehicle. Loading provision CV3: Pointer: the Class 1 quantity limits per transport unit in 7.5.5.2 apply. Operation provision S1: Class 1 operating rules: training, official escort, no smoking, loading places, 50 m spacing, supervision thresholds by division, locking. (ADR 7.2.4, V2, 7.2.4, V3, 7.5.11, CV1, 7.5.11, CV2, 7.5.11, CV3, 8.5, S1; paraphrase, not yet reviewed)