- Tunnels
- Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 3: at most 1000 per transport unit under 1.1.3.6, counted ×1 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.1 (Flammable solids, self-reactive and polymerizing substances, and solid desensitized explosives) (ADR 5.2.2.2.2, label model No. 4.1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P002: General packing instruction for solids: combination, single, composite packagings and pressure receptacles, with net mass limits by packing group. Packing instruction LP02: Solids in large packagings: glass, plastics, metal, paper or fibre inners in 50-series or 51H outers, packing group III only, up to 3 m3. Packing instruction R001: R001 permits light gauge metal packagings 0A1 and 0A2 up to 40 l / 50 kg for packing groups II and III; packing group I is not allowed. Special packing provision PP7: UN 2000 celluloid may go unpacked on film-wrapped, secured pallets of up to 1 000 kg, as a full load in closed vehicles or containers. Mixed packing provision MP11: Up to 5 kg per inner may be mixed with other codes or classes that permit it, but not Class 5.1 PG I or II, or with non-ADR goods. (ADR 4.1.4.1, P002, 4.1.4.3, LP02, 4.1.4.1, R001, 4.1.4.1, P002, PP7, 4.1.10.4, MP11; paraphrase, not yet reviewed)