- Tunnels
- Tunnel code (C/E): in tanks, Prohibited in C, D, E; in other carriage, Prohibited in E. Tanks: A, B. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 6.1 (Toxic substances), model 8 (Corrosive substances) (ADR 5.2.2.2.2, label model No. 6.1, 5.2.2.2.2, label model No. 8; paraphrase, not yet reviewed)
- Packing
- Packing instruction P002: General packing instruction for solids: combination, single, composite packagings and pressure receptacles, with net mass limits by packing group. Packing instruction IBC05: IBC05 allows metal IBCs, rigid plastics IBCs (11H1 to 31H2) and composite IBCs 11HZ1, 21HZ1 and 31HZ1. Mixed packing provision MP18: Up to 0.5 kg per inner and 1 kg per package may be mixed with other classes (not Class 7) that permit it, or with non-ADR goods. (ADR 4.1.4.1, P002, 4.1.4.2, IBC05, 4.1.10.4, MP18; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T6: Portable tank, Class 1 and 3–9: test 4 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.2. Portable tank provision TP33: The assigned tank instruction covers granular/powdered solids and solids loaded hot but carried as a solid mass. Tank code S10AH: ADR tank code for Classes 1 and 3–9: solid tank, 10 bar, openings A, hermetically closed. — S: tank for solid-state substances (powdery or granular); 10: minimum calculation pressure of 10 bar (see 6.8.2.1.14); A: filling or discharge openings at the bottom, each with 2 closures; H: hermetically closed (see 1.2.1) Tank provision TU14: Protective caps on the closures must be locked during carriage. Tank provision TU15: Tank must not be used to carry foodstuffs, articles of consumption or animal feeds. Tank provision TE19: Top fittings recessed, valved or shielded against overturning; bottom fittings recessed 200 mm or rail-protected; rear fittings behind the 9.7.6 bumper. Tank provision TE21: Closures must be protected by lockable caps. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T6, 4.2.5.3, TP33, 4.3.4.1.1, tank code S10AH, 4.3.5, TU14, 4.3.5, TU15, 6.8.4 (b), TE19, 6.8.4 (b), TE21, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V10: IBCs need a closed or sheeted vehicle, or a closed or sheeted container; open units are not allowed. Loading provision CV1: Public-place loading/unloading: special permission needed inside built-up areas, advance notice to the authorities outside them. Loading provision CV13: After a leak or spill, clean (and if needed disinfect or decontaminate) the vehicle or container before reuse; check other goods for contamination. Loading provision CV28: Pointer: the provisions of 7.5.4 apply. Operation provision S9: Any quantity: avoid service stops near inhabited or busy places; longer stops there need authority consent. Operation provision S14: Chapter 8.4 vehicle supervision applies for any amount of these substances. (ADR 7.2.4, V10, 7.5.11, CV1, 7.5.11, CV13, 7.5.11, CV28, 8.5, S9, 8.5, S14; paraphrase, not yet reviewed)