- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 0: no 1.1.3.6 exemption applies (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.3 (Substances which emit flammable gases in contact with water), model 8 (Corrosive substances) (ADR 5.2.2.2.2, label model No. 4.3, 5.2.2.2.2, label model No. 8; paraphrase, not yet reviewed)
- Packing
- Packing instruction P402: Steel pressure receptacles at 6 bar, combination packagings (glass 10 kg / metal or plastics 15 kg inners, 125 kg outer), 1A1 drums or 6HA1/6HB1 up to 250 l. Packing instruction IBC01: Liquids under IBC01 may go only in metal IBCs of types 31A, 31B or 31N, subject to the general packing rules. Special packing provision RR7: RID/ADR only: pressure receptacles for the listed substances must be tested every five years instead of ten. Special packing provision RR8: RID/ADR only: pressure receptacles for the listed substances need initial and periodic tests at no less than 1 MPa (10 bar). Mixed packing provision MP15: Up to 3 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P402, 4.1.4.2, IBC01, 4.1.4.1, P401, RR7, 4.1.4.1, P402, RR8, 4.1.10.4, MP15; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T11: Portable tank, Class 1 and 3–9: test 6 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP2: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula). Portable tank provision TP7: Air must be removed from the vapour space, by nitrogen or another method. Tank code L4DH: ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings D, hermetically closed. — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); D: filled and discharged from the top; nothing opens below the liquid surface; H: hermetically closed (see 1.2.1) Tank provision TU14: Protective caps on the closures must be locked during carriage. Tank provision TE21: Closures must be protected by lockable caps. Tank provision TM2: Tanks must additionally be marked "Do not open during carriage" and "Gives off flammable gases on contact with water". Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T11, 4.2.5.3, TP2, 4.2.5.3, TP7, 4.3.4.1.1, tank code L4DH, 4.3.5, TU14, 6.8.4 (b), TE21, 6.8.4 (e), TM2, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V1: Packages must go on a closed or sheeted vehicle or in a closed or sheeted container; open vehicles and containers are not allowed. Loading provision CV23: Take special measures when handling packages so they never come into contact with water. (ADR 7.2.4, V1, 7.5.11, CV23; paraphrase, not yet reviewed)