- Tunnels
- Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 8 (Corrosive substances) (ADR 5.2.2.2.2, label model No. 8; paraphrase, not yet reviewed)
- Packing
- Packing instruction P002: General packing instruction for solids: combination, single, composite packagings and pressure receptacles, with net mass limits by packing group. Packing instruction IBC05: IBC05 allows metal IBCs, rigid plastics IBCs (11H1 to 31H2) and composite IBCs 11HZ1, 21HZ1 and 31HZ1. Special packing provision PP9: UN 3175, 3243 and 3244 packagings need a design type that passed a PG II leakproofness test; UN 3175 is exempt if liquid fully absorbed in sealed bags. Mixed packing provision MP10: Up to 5 kg per inner packaging may be mixed with same-class goods of other codes, other classes that permit it, or non-ADR goods. (ADR 4.1.4.1, P002, 4.1.4.2, IBC05, 4.1.4.1, P002, PP9, 4.1.10.4, MP10; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T3: Portable tank, Class 1 and 3–9: test 2.65 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.2. Bulk container code BK1: Bulk carriage in sheeted bulk containers is allowed for the substance, subject to Chapter 6.11 and 7.3.2. Bulk container code BK2: Bulk carriage in closed bulk containers is allowed for the substance, subject to Chapter 6.11 and 7.3.2. Portable tank provision TP33: The assigned tank instruction covers granular/powdered solids and solids loaded hot but carried as a solid mass. Tank code SGAV: ADR tank code for Classes 1 and 3–9: solid tank, G (general minimum), openings A, valves/devices V. — S: tank for solid-state substances (powdery or granular); G: minimum calculation pressure under the general requirements of 6.8.2.1.14; A: filling or discharge openings at the bottom, each with 2 closures; V: has a 6.8.2.2.6 breather device but no flame-propagation protection, or is not explosion-pressure-shock resistant Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T3, 7.3.2.1, BK1, 7.3.2.1, BK2, 4.2.5.3, TP33, 4.3.4.1.1, tank code SGAV, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Bulk carriage VC1: Bulk carriage allowed in sheeted vehicles, sheeted containers or sheeted bulk containers (BK1 also usable if 7.3.3.2 met). Bulk carriage VC2: Bulk carriage allowed in closed vehicles, closed containers or closed bulk containers (BK2 also usable if 7.3.3.2 met). Bulk provision AP7: Bulk carriage is permitted only as a full load. (ADR 7.3.3.1, VC1, 7.3.3.1, VC2, 7.3.3.2, AP7; paraphrase, not yet reviewed)