- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 3: at most 1000 per transport unit under 1.1.3.6, counted ×1 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: Column (5) gives no label model for the entry, so no hazard label is required on packages of it unless a special provision adds one. (ADR 3.2.1, explanation of Column (5); 5.2.2.1.1; paraphrase, not yet reviewed)
- Packing
- Packing instruction P002: General packing instruction for solids: combination, single, composite packagings and pressure receptacles, with net mass limits by packing group. Packing instruction IBC08: IBC08 is the widest solids IBC instruction: metal, rigid plastics, composite, fibreboard 11G, wooden and flexible 13-series IBCs. Packing instruction R001: R001 permits light gauge metal packagings 0A1 and 0A2 up to 40 l / 50 kg for packing groups II and III; packing group I is not allowed. Special packing provision PP14: UN 2211, 2698 and 3314 packagings are exempt from the Chapter 6.1 performance tests. Special packing provision B3: Flexible IBCs must be sift-proof and water-resistant, or carry a liner that is. Special packing provision B6: For certain solids (e.g. UN 1363, 1408, 2211, 3314) the IBCs need not pass the Chapter 6.5 IBC tests. Mixed packing provision MP10: Up to 5 kg per inner packaging may be mixed with same-class goods of other codes, other classes that permit it, or non-ADR goods. (ADR 4.1.4.1, P002, 4.1.4.2, IBC08, 4.1.4.1, R001, 4.1.4.1, P002, PP14, 4.1.4.2, IBC08, B3, 4.1.4.2, IBC08, B6, 4.1.10.4, MP10; paraphrase, not yet reviewed)
- Carriage
- Bulk carriage VC1: Bulk carriage allowed in sheeted vehicles, sheeted containers or sheeted bulk containers (BK1 also usable if 7.3.3.2 met). Bulk carriage VC2: Bulk carriage allowed in closed vehicles, closed containers or closed bulk containers (BK2 also usable if 7.3.3.2 met). Bulk provision AP2: For VC bulk carriage, the vehicle or container must be adequately ventilated. Loading provision CV36: Prefer open or ventilated units; if closed, isolate the cab from the load and mark doors "WARNING NO VENTILATION OPEN WITH CAUTION" (≥ 25 mm). (ADR 7.3.3.1, VC1, 7.3.3.1, VC2, 7.3.3.2, AP2, 7.5.11, CV36; paraphrase, not yet reviewed)