- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.3 (Substances which emit flammable gases in contact with water) (ADR 5.2.2.2.2, label model No. 4.3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P410: Solids of PG II/III: combination, single drums, jerricans, boxes, bags, composites and pressure receptacles, with net mass limits. Packing instruction IBC04: Solids under IBC04 may go only in metal IBCs (11A, 11B, 11N, 21A, 21B, 21N, 31A, 31B, 31N). Mixed packing provision MP14: Up to 6 kg per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P410, 4.1.4.2, IBC04, 4.1.10.4, MP14; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T3: Portable tank, Class 1 and 3–9: test 2.65 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.2. Portable tank provision TP33: The assigned tank instruction covers granular/powdered solids and solids loaded hot but carried as a solid mass. Portable tank provision TP36: Fusible elements may be fitted in the vapour space of the portable tank. Portable tank provision TP41: With competent authority agreement, the 2.5-year internal examination may be waived for tanks dedicated to these organometallics. Tank code SGAN: ADR tank code for Classes 1 and 3–9: solid tank, G (general minimum), openings A, valves/devices N. — S: tank for solid-state substances (powdery or granular); G: minimum calculation pressure under the general requirements of 6.8.2.1.14; A: filling or discharge openings at the bottom, each with 2 closures; N: has no 6.8.2.2.6 breather device and is not hermetically closed Tank code L4DH: ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings D, hermetically closed. — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); D: filled and discharged from the top; nothing opens below the liquid surface; H: hermetically closed (see 1.2.1) Tank provision TU14: Protective caps on the closures must be locked during carriage. Tank provision TE21: Closures must be protected by lockable caps. Tank provision TM2: Tanks must additionally be marked "Do not open during carriage" and "Gives off flammable gases on contact with water". Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T3, 4.2.5.3, TP33, 4.2.5.3, TP36, 4.2.5.3, TP41, 4.3.4.1.1, tank code SGAN, 4.3.4.1.1, tank code L4DH, 4.3.5, TU14, 6.8.4 (b), TE21, 6.8.4 (e), TM2, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V1: Packages must go on a closed or sheeted vehicle or in a closed or sheeted container; open vehicles and containers are not allowed. Loading provision CV23: Take special measures when handling packages so they never come into contact with water. (ADR 7.2.4, V1, 7.5.11, CV23; paraphrase, not yet reviewed)