- Tunnels
- Tunnel code (B/E): in tanks, Prohibited in B, C, D, E; in other carriage, Prohibited in E. Tanks: A only. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 0: no 1.1.3.6 exemption applies (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.3 (Substances which emit flammable gases in contact with water) (ADR 5.2.2.2.2, label model No. 4.3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P402: Steel pressure receptacles at 6 bar, combination packagings (glass 10 kg / metal or plastics 15 kg inners, 125 kg outer), 1A1 drums or 6HA1/6HB1 up to 250 l. Mixed packing provision MP2: No mixed packing: the goods must be alone in their package. (ADR 4.1.4.1, P402, 4.1.10.4, MP2; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T13: Portable tank, Class 1 and 3–9: test 6 bar; shell 6 mm; relief Normal; bottom openings Not allowed. Portable tank provision TP2: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula). Portable tank provision TP7: Air must be removed from the vapour space, by nitrogen or another method. Portable tank provision TP36: Fusible elements may be fitted in the vapour space of the portable tank. Portable tank provision TP41: With competent authority agreement, the 2.5-year internal examination may be waived for tanks dedicated to these organometallics. Tank code L10DH: ADR tank code for Classes 1 and 3–9: liquid tank, 10 bar, openings D, hermetically closed. — L: tank for liquid-state substances (liquids, or solids handed over molten); 10: minimum calculation pressure of 10 bar (see 6.8.2.1.14); D: filled and discharged from the top; nothing opens below the liquid surface; H: hermetically closed (see 1.2.1) Tank provision TU4: Cargo kept under an inert gas blanket of 50 kPa (0.5 bar) gauge or more; uncleaned empty tanks likewise charged with inert gas. Tank provision TU14: Protective caps on the closures must be locked during carriage. Tank provision TU22: Fill to no more than 90 % of capacity; for liquids leave 5 % empty at an average liquid temperature of 50 °C. Tank provision TE21: Closures must be protected by lockable caps. Tank provision TM2: Tanks must additionally be marked "Do not open during carriage" and "Gives off flammable gases on contact with water". Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T13, 4.2.5.3, TP2, 4.2.5.3, TP7, 4.2.5.3, TP36, 4.2.5.3, TP41, 4.3.4.1.1, tank code L10DH, 4.3.5, TU4, 4.3.5, TU14, 4.3.5, TU22, 6.8.4 (b), TE21, 6.8.4 (e), TM2, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V1: Packages must go on a closed or sheeted vehicle or in a closed or sheeted container; open vehicles and containers are not allowed. Loading provision CV23: Take special measures when handling packages so they never come into contact with water. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 7.2.4, V1, 7.5.11, CV23, 8.5, S20; paraphrase, not yet reviewed)