- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 0: no 1.1.3.6 exemption applies (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.3 (Substances which emit flammable gases in contact with water), model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 4.3, 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Packing instruction IBC01: Liquids under IBC01 may go only in metal IBCs of types 31A, 31B or 31N, subject to the general packing rules. Mixed packing provision MP15: Up to 3 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.4.2, IBC01, 4.1.10.4, MP15; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T7: Portable tank, Class 1 and 3–9: test 4 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP2: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula). Portable tank provision TP7: Air must be removed from the vapour space, by nitrogen or another method. Portable tank provision TP36: Fusible elements may be fitted in the vapour space of the portable tank. Portable tank provision TP41: With competent authority agreement, the 2.5-year internal examination may be waived for tanks dedicated to these organometallics. Tank code L4DH: ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings D, hermetically closed. — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); D: filled and discharged from the top; nothing opens below the liquid surface; H: hermetically closed (see 1.2.1) Tank provision TU4: Cargo kept under an inert gas blanket of 50 kPa (0.5 bar) gauge or more; uncleaned empty tanks likewise charged with inert gas. Tank provision TU14: Protective caps on the closures must be locked during carriage. Tank provision TU22: Fill to no more than 90 % of capacity; for liquids leave 5 % empty at an average liquid temperature of 50 °C. Tank provision TE21: Closures must be protected by lockable caps. Tank provision TM2: Tanks must additionally be marked "Do not open during carriage" and "Gives off flammable gases on contact with water". Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.2.5.2.6, portable tank instruction T7, 4.2.5.3, TP2, 4.2.5.3, TP7, 4.2.5.3, TP36, 4.2.5.3, TP41, 4.3.4.1.1, tank code L4DH, 4.3.5, TU4, 4.3.5, TU14, 4.3.5, TU22, 6.8.4 (b), TE21, 6.8.4 (e), TM2, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V1: Packages must go on a closed or sheeted vehicle or in a closed or sheeted container; open vehicles and containers are not allowed. Loading provision CV23: Take special measures when handling packages so they never come into contact with water. Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. (ADR 7.2.4, V1, 7.5.11, CV23, 8.5, S2; paraphrase, not yet reviewed)