- Tunnels
- Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 0: no 1.1.3.6 exemption applies (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 5.1 (Oxidizing substances) (ADR 5.2.2.2.2, label model No. 5.1; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T7: Portable tank, Class 1 and 3–9: test 4 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP1: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.2 (the 97-based formula). Portable tank provision TP16: Tank must have an approved device against under- and over-pressure; relief per 6.7.2.8.3 to stop crystallization. Portable tank provision TP17: Thermal insulation of the tank may only use inorganic, non-combustible materials. Tank code L4BV(+): ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings B, valves/devices V, suffix (+). — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); B: filling or discharge openings at the bottom, each with 3 closures; V: has a 6.8.2.2.6 breather device but no flame-propagation protection, or is not explosion-pressure-shock resistant; (+): alternative use of the tank for other substances is allowed only where the certificate of type approval says so (3.2.1 column (12); 4.3.4.1.3) Tank provision TU3: Shell interior and every part touching the substance kept clean; no lubricant that could react dangerously with it on pumps or valves. Tank provision TU12: When the tank changes use, shell and equipment must be thoroughly cleaned of residues before and after carrying this substance. Tank provision TU29: Tanks may be filled to no more than 97 % of capacity, and the temperature after filling must not exceed 140 °C. Tank provision TC3: Shells must be made of austenitic steel. Tank provision TE9: A top-mounted shut-off device must stop pressure build-up from decomposition, liquid leakage and entry of foreign matter. Tank provision TE10: Shut-off devices must not be blockable by solidified cargo; any insulation must be inorganic and free of combustible matter. Tank provision TA1: Tanks must not be approved for carrying organic substances. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T7, 4.2.5.3, TP1, 4.2.5.3, TP16, 4.2.5.3, TP17, 4.3.4.1.1, tank code L4BV(+), 4.3.5, TU3, 4.3.5, TU12, 4.3.5, TU29, 6.8.4 (a), TC3, 6.8.4 (b), TE9, 6.8.4 (b), TE10, 6.8.4 (c), TA1, 9.1.1.2, AT vehicle; paraphrase, not yet reviewed)
- Carriage
- Operation provision S23: Chapter 8.4 supervision applies in bulk or tanks above 3 000 kg or 3 000 litres; not triggered for packaged carriage. (ADR 8.5, S23; paraphrase, not yet reviewed)