UN 1133 (variant 1 of 6, packing group I) — ADR 2025 Table A: class 3, classification code F1, packing group I, labels 3, special provisions —, limited quantity 500 ml, excepted quantity E3, packing instructions P001, transport category 1, tunnel restriction code (D/E), hazard identification number 33.
UN 1133 (variant 2 of 6, packing group II) — ADR 2025 Table A: class 3, classification code F1, packing group II, labels 3, special provisions 640C, limited quantity 5 L, excepted quantity E2, packing instructions P001, transport category 2, tunnel restriction code (D/E), hazard identification number 33.
UN 1133 (variant 3 of 6, packing group II) — ADR 2025 Table A: class 3, classification code F1, packing group II, labels 3, special provisions 640D, limited quantity 5 L, excepted quantity E2, packing instructions P001 IBC02 R001, transport category 2, tunnel restriction code (D/E), hazard identification number 33.
UN 1133 (variant 4 of 6, packing group III) — ADR 2025 Table A: class 3, classification code F1, packing group III, labels 3, special provisions —, limited quantity 5 L, excepted quantity E1, packing instructions P001 IBC03 LP01 R001, transport category 3, tunnel restriction code (D/E), hazard identification number 30.
UN 1133 (variant 5 of 6, packing group III) — ADR 2025 Table A: class 3, classification code F1, packing group III, labels 3, special provisions —, limited quantity 5 L, excepted quantity E1, packing instructions P001 R001, transport category 3, tunnel restriction code (E), hazard identification number —.
UN 1133 (variant 6 of 6, packing group III) — ADR 2025 Table A: class 3, classification code F1, packing group III, labels 3, special provisions —, limited quantity 5 L, excepted quantity E1, packing instructions P001 IBC02 R001, transport category 3, tunnel restriction code (E), hazard identification number —.
UNECE ADR 2025, ECE/TRANS/352 · checked 2026-10-28
In plain words — variant 1 of 6, packing group I
- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Mixed packing provision MP7: Up to 5 litres per inner packaging may be mixed with same-class goods of other classification codes or with non-ADR goods. Mixed packing provision MP17: Up to 0.5 litre per inner and 1 litre per package may be mixed with other classes (not Class 7) that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.10.4, MP7, 4.1.10.4, MP17; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T11: Portable tank, Class 1 and 3–9: test 6 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP1: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.2 (the 97-based formula). Portable tank provision TP8: Test pressure may drop to 1.5 bar when the substances carried have a flash point above 0 °C. Portable tank provision TP27: A 4 bar minimum test pressure tank may be used if 4 bar or less is shown acceptable under 6.7.2.1. Tank code L4BN: ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings B, valves/devices N. — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); B: filling or discharge openings at the bottom, each with 3 closures; N: has no 6.8.2.2.6 breather device and is not hermetically closed Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.2.5.2.6, portable tank instruction T11, 4.2.5.3, TP1, 4.2.5.3, TP8, 4.2.5.3, TP27, 4.3.4.1.1, tank code L4BN, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 8.5, S2, 8.5, S20; paraphrase, not yet reviewed)
Assembled from FreightUtils' meanings of the Table A codes, not the official text. A statement marked “not yet reviewed” has not yet been checked against ADR by a person.
In plain words — variant 2 of 6, packing group II
- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Special packing provision PP1: Small (≤ 5 L) metal or plastics packagings of certain paints, inks, adhesives etc. in PG II/III need no Chapter 6.1 tests if palletized or inner. Mixed packing provision MP19: Up to 5 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.4.1, P001, PP1, 4.1.10.4, MP19; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T4: Portable tank, Class 1 and 3–9: test 2.65 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP1: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.2 (the 97-based formula). Portable tank provision TP8: Test pressure may drop to 1.5 bar when the substances carried have a flash point above 0 °C. Tank code L1.5BN: ADR tank code for Classes 1 and 3–9: liquid tank, 1.5 bar, openings B, valves/devices N. — L: tank for liquid-state substances (liquids, or solids handed over molten); 1.5: minimum calculation pressure of 1.5 bar (see 6.8.2.1.14); B: filling or discharge openings at the bottom, each with 3 closures; N: has no 6.8.2.2.6 breather device and is not hermetically closed Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.2.5.2.6, portable tank instruction T4, 4.2.5.3, TP1, 4.2.5.3, TP8, 4.3.4.1.1, tank code L1.5BN, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 8.5, S2, 8.5, S20; paraphrase, not yet reviewed)
Assembled from FreightUtils' meanings of the Table A codes, not the official text. A statement marked “not yet reviewed” has not yet been checked against ADR by a person.
In plain words — variant 3 of 6, packing group II
- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 2: at most 333 per transport unit under 1.1.3.6, counted ×3 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Packing instruction IBC02: Liquids under IBC02 may use metal (31A/31B/31N), rigid plastics (31H1/31H2) or composite 31HZ1 IBCs, with B and BB limits per UN number. Packing instruction R001: R001 permits light gauge metal packagings 0A1 and 0A2 up to 40 l / 50 kg for packing groups II and III; packing group I is not allowed. Special packing provision PP1: Small (≤ 5 L) metal or plastics packagings of certain paints, inks, adhesives etc. in PG II/III need no Chapter 6.1 tests if palletized or inner. Mixed packing provision MP19: Up to 5 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.4.2, IBC02, 4.1.4.1, R001, 4.1.4.1, P001, PP1, 4.1.10.4, MP19; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T4: Portable tank, Class 1 and 3–9: test 2.65 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP1: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.2 (the 97-based formula). Portable tank provision TP8: Test pressure may drop to 1.5 bar when the substances carried have a flash point above 0 °C. Tank code LGBF: ADR tank code for Classes 1 and 3–9: liquid tank, G (general minimum), openings B, valves/devices F. — L: tank for liquid-state substances (liquids, or solids handed over molten); G: minimum calculation pressure under the general requirements of 6.8.2.1.14; B: filling or discharge openings at the bottom, each with 3 closures; F: has a 6.8.2.2.6 breather device fitted with flame-propagation protection, or is explosion-pressure-shock resistant Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.2.5.2.6, portable tank instruction T4, 4.2.5.3, TP1, 4.2.5.3, TP8, 4.3.4.1.1, tank code LGBF, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. Operation provision S20: Chapter 8.4 supervision applies above 10 000 kg in packages, or above 3 000 litres in tanks. (ADR 8.5, S2, 8.5, S20; paraphrase, not yet reviewed)
Assembled from FreightUtils' meanings of the Table A codes, not the official text. A statement marked “not yet reviewed” has not yet been checked against ADR by a person.
In plain words — variant 4 of 6, packing group III
- Tunnels
- Tunnel code (D/E): in tanks, Prohibited in D, E (bulk or tanks); in other carriage, Prohibited in E. Bulk/tanks: A, B, C. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 3: at most 1000 per transport unit under 1.1.3.6, counted ×1 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Packing instruction IBC03: Liquids under IBC03 may use metal 31-series, rigid plastics 31H1/31H2 or a wider set of 31H composite IBCs. Packing instruction LP01: Liquids in large packagings: glass, plastics or metal inners in 50-series outers, packing group III only, up to 3 m3. Packing instruction R001: R001 permits light gauge metal packagings 0A1 and 0A2 up to 40 l / 50 kg for packing groups II and III; packing group I is not allowed. Special packing provision PP1: Small (≤ 5 L) metal or plastics packagings of certain paints, inks, adhesives etc. in PG II/III need no Chapter 6.1 tests if palletized or inner. Mixed packing provision MP19: Up to 5 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.4.2, IBC03, 4.1.4.3, LP01, 4.1.4.1, R001, 4.1.4.1, P001, PP1, 4.1.10.4, MP19; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T2: Portable tank, Class 1 and 3–9: test 1.5 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP1: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.2 (the 97-based formula). Tank code LGBF: ADR tank code for Classes 1 and 3–9: liquid tank, G (general minimum), openings B, valves/devices F. — L: tank for liquid-state substances (liquids, or solids handed over molten); G: minimum calculation pressure under the general requirements of 6.8.2.1.14; B: filling or discharge openings at the bottom, each with 3 closures; F: has a 6.8.2.2.6 breather device fitted with flame-propagation protection, or is explosion-pressure-shock resistant Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.2.5.2.6, portable tank instruction T2, 4.2.5.3, TP1, 4.3.4.1.1, tank code LGBF, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V12: IBCs of type 31HZ2 (31HA2, 31HB2, 31HN2, 31HD2, 31HH2) must be carried in closed vehicles or closed containers. Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. (ADR 7.2.4, V12, 8.5, S2; paraphrase, not yet reviewed)
Assembled from FreightUtils' meanings of the Table A codes, not the official text. A statement marked “not yet reviewed” has not yet been checked against ADR by a person.
In plain words — variant 5 of 6, packing group III
- Tunnels
- Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 3: at most 1000 per transport unit under 1.1.3.6, counted ×1 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Packing instruction R001: R001 permits light gauge metal packagings 0A1 and 0A2 up to 40 l / 50 kg for packing groups II and III; packing group I is not allowed. Special packing provision PP1: Small (≤ 5 L) metal or plastics packagings of certain paints, inks, adhesives etc. in PG II/III need no Chapter 6.1 tests if palletized or inner. Mixed packing provision MP19: Up to 5 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.4.1, R001, 4.1.4.1, P001, PP1, 4.1.10.4, MP19; paraphrase, not yet reviewed)
- Carriage
- Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. (ADR 8.5, S2; paraphrase, not yet reviewed)
Assembled from FreightUtils' meanings of the Table A codes, not the official text. A statement marked “not yet reviewed” has not yet been checked against ADR by a person.
In plain words — variant 6 of 6, packing group III
- Tunnels
- Tunnel code (E): in tanks, Prohibited in E; in other carriage, Prohibited in E. Every category except E. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 3: at most 1000 per transport unit under 1.1.3.6, counted ×1 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Packing instruction IBC02: Liquids under IBC02 may use metal (31A/31B/31N), rigid plastics (31H1/31H2) or composite 31HZ1 IBCs, with B and BB limits per UN number. Packing instruction R001: R001 permits light gauge metal packagings 0A1 and 0A2 up to 40 l / 50 kg for packing groups II and III; packing group I is not allowed. Special packing provision PP1: Small (≤ 5 L) metal or plastics packagings of certain paints, inks, adhesives etc. in PG II/III need no Chapter 6.1 tests if palletized or inner. Special packing provision BB4: RID/ADR only: listed flammable liquids in packing group III under 2.2.3.1.4 may not use IBCs above 450 litres. Mixed packing provision MP19: Up to 5 litres per inner packaging may be mixed with goods of other codes or classes that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.4.2, IBC02, 4.1.4.1, R001, 4.1.4.1, P001, PP1, 4.1.4.2, IBC02, BB4, 4.1.10.4, MP19; paraphrase, not yet reviewed)
- Carriage
- Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. (ADR 8.5, S2; paraphrase, not yet reviewed)
Assembled from FreightUtils' meanings of the Table A codes, not the official text. A statement marked “not yet reviewed” has not yet been checked against ADR by a person.