- Tunnels
- Tunnel code (C/E): in tanks, Prohibited in C, D, E; in other carriage, Prohibited in E. Tanks: A, B. Packages: A, B, C, D. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 6.1 (Toxic substances), model 3 (Flammable liquids) (ADR 5.2.2.2.2, label model No. 6.1, 5.2.2.2.2, label model No. 3; paraphrase, not yet reviewed)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Mixed packing provision MP8: Up to 3 litres per inner packaging may be mixed with same-class goods of other classification codes or with non-ADR goods. Mixed packing provision MP17: Up to 0.5 litre per inner and 1 litre per package may be mixed with other classes (not Class 7) that permit it, or with non-ADR goods. (ADR 4.1.4.1, P001, 4.1.10.4, MP8, 4.1.10.4, MP17; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T14: Portable tank, Class 1 and 3–9: test 6 bar; shell 6 mm; relief See 6.7.2.8.3; bottom openings Not allowed. Portable tank provision TP2: Portable tank must not be filled beyond the degree of filling set by 4.2.1.9.3 (the 95-based formula). Portable tank provision TP27: A 4 bar minimum test pressure tank may be used if 4 bar or less is shown acceptable under 6.7.2.1. Tank code L10CH: ADR tank code for Classes 1 and 3–9: liquid tank, 10 bar, openings C, hermetically closed. — L: tank for liquid-state substances (liquids, or solids handed over molten); 10: minimum calculation pressure of 10 bar (see 6.8.2.1.14); C: filled and discharged from the top; below the liquid surface there are cleaning openings only; H: hermetically closed (see 1.2.1) Tank provision TU14: Protective caps on the closures must be locked during carriage. Tank provision TU15: Tank must not be used to carry foodstuffs, articles of consumption or animal feeds. Tank provision TE19: Top fittings recessed, valved or shielded against overturning; bottom fittings recessed 200 mm or rail-protected; rear fittings behind the 9.7.6 bumper. Tank provision TE21: Closures must be protected by lockable caps. Vehicle for tank carriage: FL — Vehicle for flammable liquids (flash point ≤ 60 °C), flammable gases or UN 2015 > 60 % in tanks above set sizes. (ADR 4.2.5.2.6, portable tank instruction T14, 4.2.5.3, TP2, 4.2.5.3, TP27, 4.3.4.1.1, tank code L10CH, 4.3.5, TU14, 4.3.5, TU15, 6.8.4 (b), TE19, 6.8.4 (b), TE21, 9.1.1.2, FL vehicle; paraphrase, not yet reviewed)
- Carriage
- Loading provision CV1: Public-place loading/unloading: special permission needed inside built-up areas, advance notice to the authorities outside them. Loading provision CV13: After a leak or spill, clean (and if needed disinfect or decontaminate) the vehicle or container before reuse; check other goods for contamination. Loading provision CV28: Pointer: the provisions of 7.5.4 apply. Operation provision S2: Flammable liquids/gases: no ordinary portable lights in closed load compartments; FL heaters off during loading; earth FL vehicles before filling. Operation provision S9: Any quantity: avoid service stops near inhabited or busy places; longer stops there need authority consent. Operation provision S14: Chapter 8.4 vehicle supervision applies for any amount of these substances. (ADR 7.5.11, CV1, 7.5.11, CV13, 7.5.11, CV28, 8.5, S2, 8.5, S9, 8.5, S14; paraphrase, not yet reviewed)